Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
3-28
[ S E R I E S / P A R A L L E L ]
M A S T E R O R S L A V E = M A S T E R
M / S T E R M I N A T O R
= D I S A B L E
P A R A L L E L O R S E R I E S
= P A R A L L E L _
N U M . O F S L A V E
= 1
M A S T E R & S L A V E C O N T R O L = N O
Figure 3-41
2.
Use the numeric (
0
~
1
) keys or “Rotary” (
) knob to set PARALLEL or
SERIES.
Connect the cables on the rear panel as Figure 3-34 shows when set to SERIES and as
Figure 3-35 shows when set to PARALLEL.
Select SERIES will prompt the following window as Figure 3-42 shows to remind the
user to disconnect the CURRENT SHARING cable on the rear panel.
[ S E R I E S / P A R A L L E L ]
M A S T E R O R S L A V E = M A S T E R
M / S T E R M I N A T O R
= D I S A B L E
P A R A L L E L O R S E R I E S
= S E R I E S _
N U M . O F S L A V E
= 1
M A S T E R & S L A V E C O N T R O L = N O
D I S C O N N E C T T H E C U R R E N T S H A R I N G C A B L E T O
P
R E V E N T D A M A G E A T S E R I E S
Figure 3-42
3.
Press “
ENTER
” to confirm.
4.
Press “
EXIT
” to return to the MAIN PAGE.
3.3.3.3.4
Setting NUM. OF SLAVE
Take example by 62150H-600S, when the DC Power Supply is set to MASTER, the
controlled number that is the SLAVE number has to be set as well. If the controlled sets are
4, then set NUM. OF SLAVE = 4 as Figure 3-43 shown below.
1.
Use “
”, “
” keys to move the cursor to the column to be set.
2.
Use the numeric (
0
~
1
) keys or “Rotary” (
) knob to set the number of
SLAVE.