Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
3-44
1.
Selecting DISABLE:
It closes the function.
2.
Selecting ENABLE:
It sets the REMOTE INHIBIT to ENABLE. The DC Power
Supply’s ON/OFF is still controlled by “
ON/OFF
” key. When
Pin9 (_INHIBIT) of ANALOG INTERFACE is triggered by a
Low Level that equals to press the “
ON/OFF
” key on the
front panel and set OUTPUT = OFF, the DC Power Supply
will shut down and sends out a protection signal (in this
case the “
ON/OFF
” will be off.) It cannot use Pin9 (_INHIBIT)
of the ANALOG INTERFACE to release the protection.
3.
Press “
ENTER
” to confirm.
4.
Press
“
EXIT
” to return to the MAIN PAGE.
3.
When protection occurs due to the REMOTE INHIBIT the main page will display the
protection message as Figure 3-76 shows.
V = 6 0. 0 0 V I = 1 0. 0 0 _ A O F F
0 . 0 0 0 0 V 0 . 0 0 0 0 A
I H B 0 . 0 W
Figure 3-76
4.
Furthermore, Pin9 is an input pin of TTL Level and is able to set the initial state to
PULL=HIGH or PULL=LOW.
5.
When the DC Power Supply is set to OUTPUT = ON, the detail actions of REMOTE
INHIBIT are shown in Figure 3-77.