Programmable AC/DC Electronic Load 63800 Series Operation & Programming Manual
3-18
I s e t = 5 . 0 0 0 C F = 1 . 4 1 4 P F = 1 . 0 0 0
I p ( m a x ) = 1 0 . 0 U N I T : A
4. Press
1
,
.
,
5
then press
ENTER
to change the value to “1.500”.
I s e t = 5 . 0 0 0 C F = 1 . 5 0 0 P F = 1 . 0 0 0
I p ( m a x ) = 1 0 . 0 U N I T : A
5. Move the cursor by pressing (
◄
,
►
) to the command line of “PF=”.
I s e t = 5 . 0 0 0 C F = 1 . 5 0 0 P F = 1 . 0 0 0
I p ( m a x ) = 1 0 . 0 U N I T : A
6. Press
0
,
.
,
8
then press
ENTER
to change the value to “0.800”.
I s e t = 5 . 0 0 0 C F = 1 . 5 0 0 P F = 0 . 8 0 0
I p ( m a x ) = 1 0 . 0 U N I T : A
7. Move the cursor by pressing (
◄
,
►
) to the command line of “I
p
(max)=”.
I s e t = 5 . 0 0 0 C F = 1 . 5 0 0 P F = 0 . 8 0 0
I p ( m a x ) = 1 0 . 0 U N I T : A
8. Press
2
,
0
then press
ENTER
to change the value to “20.0”.
I s e t = 5 . 0 0 0 C F = 1 . 5 0 0 P F = 0 . 8 0 0
I p ( m a x ) = 2 0 . 0 U N I T : A
9. After setting the parameter of the load, the
LOAD ON/OFF
key should be pressed to turn
on the load, so that the load can sink the current. (For More detailed information please
refers
section 3.4.5
If there is an error during the procedure of inputting value, press
CLEAR
to
clear at any time and then input again.
3.6.2 CF Only
For switching CF only mode, the procedures are as below:
1. Press
CONF./LOCAL
key.