background image

Model

All specifications are subject to change without notice.

Statistical report

Chroma PowerPro III software provides off-the-shelf statistic report

function. All the test conditions defined in the test program and the

test readings can be stored and analyzed by statistic report

function. In statistic report function, it provides process capability,

Pareto, Xbar-R chart, Xbar-S chart, nP chart, P chart, U chart and

C chart. Users may select test program, test date period and even

include test data from remote computer via network connections.

Then choose any one of the control chart to generate statistical

report. The report may be printed out or stored in file. Or users may

store the raw data as a text file directly which is able to be imported

by Excel or similar word processor software package for further

analysis.    

2-8. Complete system administration

Management function

Chroma PowerPro III provides a series of management functions for advance system control and management.

User function allows users to define authorized person list and their authorized level. 

Activity log records the historical log-in, log-out time and activated functions of the system users. 

Users are allowed to define the release flags of test programs and test items. These flags will be used to check

if the test program can be executed by GO/ NG run. Or if the test item can be shown in user test item library.

Instrument function is used to import and export H/ W instrument drivers.

Network function provides interface for PowerPro III to communicate with external software package or system.

For example, Shop-Floor or Product-Data-Management system.  It is also used to define the source location of

the test programs when users want to centralize them.

Management

User Function

Activity log

Release

Instrument

Network

Hardware configuration

The hardware configuration function allows users to define the

system configuration by selecting devices from the instrument list

defined in the 

Instrument

section of Management function.

Shop-Floor control system

For modern mass production line, it is a big challenge to have the

full control of the scenarios happened on production line.

Therefore, Shop-Floor control system is wildly used to improve

fabrication process.

To  satisfy customers

requirement, Chroma also provides

customized Shop-Floor control system. For details, please contact

your local representative of Chroma ATE INC.

Example of statistic report process capability

Parallel setting for E-loads allow users to control

multiple load channels as one.

Summary of Contents for 8000

Page 1: ...stic and management functions making the system capable to generate various test documents and performing system administration Because the test and statistical reports are critically important in modern factories for R D evaluation QA verification and production tests these functions are an integral part of the system Working under Window98 2000 XP the model 8000 provides test engineers with a de...

Page 2: ... to the variety of the UUTs And unlimited customized or user defined test items are allowed OUTPUT PERFORMANCES 1 DC output voltage 2 DC output current 3 Peak Peak noise 4 RMS noise 5 Current ripple 6 Efficiency 7 In test adjustment 8 Power good signal 9 Power fail signal 10 P S ON signal 11 Extended measure 12 Waveform capture 13 Overshoot voltage INPUT CHARACTERISTICS 14 Inrush current 15 Input ...

Page 3: ... By using these standard instrument drivers PowerPro III can incoporated almost any modern test device Higher compatibility Application Programming Interface When users want to change the equipment from one brand to the others for traditional ATS design users are prohibited to do that The main problem is caused by the different format of the remote commands Chroma PowerPro III provides a unique ap...

Page 4: ...or also provides global variables for advanced control test requirement For instance it may be used for auto alignment system which need to pass the aligned value of the previous UUT as the next UUT s default value In this way it is very helpful to improve the align speed Sequential and Batch testing The program editor The test program editor provides a useful means to link several pre defined tes...

Page 5: ...ll Users may achieve all the instrument on system to control them and get readings from them The type of reading showing on display could be selected by user and user may even define specifications for them Furthermore user can also select them to show as a time graph in order to see the trends And the waveform measured by DSO can be merged onto the same display as well The waveform can be downloa...

Page 6: ...a PowerPro III its outstanding report wizard and generator provide the total solution for any documentation requirement From tabular test data DSO waveform to correlation chart it allows users to integrate different types of presentation in the same report Users may also edit and store report format for next use thus it saves a lot of precious time in creating test report Meanwhile to make the tes...

Page 7: ...rs Users are allowed to define the release flags of test programs and test items These flags will be used to check if the test program can be executed by GO NG run Or if the test item can be shown in user test item library Instrument function is used to import and export H W instrument drivers Network function provides interface for PowerPro III to communicate with external software package or sys...

Page 8: ...200F 5 Connection Panel Interface to UUT 6 Digital Multi Meter HP 34401A Other types or brand of DMM supported upon request 7 Power Analyzer Model 6630 6632 series Power Analyzer 8 System Controller Industrial PC 9 OVP Short Circuit Tester Model 6012 80612 10 ON OFF Controller Model 6013 80613 11 AC Source Model 6100 6400 6500 61500 61600 series AC Source 12 System Power Inlet 1Ø 3W 30A 60A select...

Page 9: ...No Yes No No DC power source Chroma power supply auto test system model 8000 supports all Chroma Model 6200 6200K and 6200F series DC power sources which may be used as line in or OVP sources MODEL 6200 series 6200K series 6200F series Power rating 60 1000W 1000 3000W 1200 12000W Voltage range 0 5V 150V 0 5V 600V 0 5V 600V Programmable current limit Yes Yes Yes Programmable OV point Yes Yes Yes An...

Page 10: ... provides an unique timing noise analyzer Chroma Model 6011 Its modular design allows users to expand up to 10 input measurement modules Each module is capable of measuring timing period and noise level Furthermore it also provides 16 bits TTL signals and 6 pairs of floating relays for external control Meanwhile the 10 multiplexer inputs and 2 DMM and 2 DSO outputs further extend the Chroma Model ...

Page 11: ...information 8000 Switching Power Supply ATS 6011 80611 Timing Noise Analyzer 6011n 6012n Timing Noise module 6012 80612 OVP Short Circuit Tester 6013 80613 ON OFF Controller 5004ATM System Controller A600009 GPIB Cable 200 cm A600010 GPIB Cable 60 cm A800004 19 Rack for Model 8000 A800005 PCI Bus GPIB Card National Instrument A800006 Test Fixture for Model 8000 Application selection guide A800010 ...

Page 12: ...tp www chromaate com E mail chroma chroma com tw U S A CHROMA ATE INC U S A 7 Chrysler Irvine CA 92618 Tel 1 949 421 0355 Fax 1 949 421 0353 Toll Free 1 800 478 2026 EUROPE CHROMA ATE EUROPE B V Max Planckstraat 4 6716 BE Ede The Netherlands Tel 31 318 648282 Fax 31 318 648288 CHINA CHROMA ELECTRONICS Shen Zhen Co Ltd 8F No 4 Nanyou Tian An Industrial Estate Shen Zhen China PC 518052 Tel 86 755 26...

Reviews: