Appendix A.2
DEFAULT CONFIGURATION PARAM-
ETERS
The configuration parameters can be loaded with
predetermined default values. These data are the
typical values loaded in the instrument prior to
shipment from factory. To load the default values
proceed as follows:
a) The internal switch (V101, see fig. 13) should
be open.
b) The upper display will show:
c) Push the
t
pushbutton; the display will show
the firmware version.
d) Maintaining the pressure on the
t
pushbutton
push the
s
pushbutton also.
The instrument will show:
e) Press
s
pushbutton to select between table 1
(European) or table 2 (American) default set
of parameters; the display will show:
f) Press FUNC pushbutton; the display will show:
This means that the loading procedure has been
initiated. After about 3 seconds the loading
procedure is terminated and the instrument
reverts to visualization as in point b).
PARA.
TABLE 1
TABLE 2
SEr 1
ErO
ER0
SEr 2
1
1
SEr 3
19200
19200
SEr 4
7E
7E
P1
3
21
P2
----.
----.
P3
0
0
P4
400
1000
P5
rEV
rEV
P6
0-20
0-20
P7
0
0
P8
400
1000
P9
nonE
nonE
P10
H.A.
H.A.
P11
nonE
nonE
P12
H.A.
H.A.
P13
OPrt.
OPrt
P14
0
0
P15
0.1
0.1
P16
0
0
P17
0
0
P18
norL
norL
P19
norL
norL
P20
norL
norL
P21
norL
norL
P22
Air
Air
P23
OFF
OFF
P24
rEV
rEV
P25
OFF
OFF
P26
rEV
rEV
P27
OFF
OFF
P28
0
0
C O n F
C O n F
A. 0 0
O F F
d F L t
t b. 1
d F L t
L O A d
1604-7-A-AB.p65
5/16/00, 10:50 AM
2