English
–
V.202106
USB and Ethernet Stand Alone interface
19
Datasheet / Technical manual
Click to enable the option
Click to enable the Play in priority option:
The scene will keep playing. No other triggers will be allowed (contacts, Infrared,
DMX) while the scene is playing (except Time/calendar schedules and buttons)
OTHER ADVANCED TRIGGER OPTIONS
Scene recovery after power off
The interface can recall the last scene played before power is cut off, and recover that scene
when the power is restored.
Each scene has the option to select
“Restore if power off”
Scene trigger priority
When several scenes have the same time trigger (date + hour + minute), only the first scene in the
list will be triggered. The rest will be ignored.
The “Play in Priority” option
allows to play a scene in priority and ignore all the other triggers
(except the buttons and clock).
ZONE SETTINGS AND CONFIGURATION
The interface has the capability to play 1scene per zone and up to 5 zones at the same time in Stand Alone mode.
It is possible to extend the last zone over several universes using a Master / Slave daisy chain of multiple interfaces.
The Master interface stores all five zones in memory and its last zone drives the Slave interfaces, which only have the last
zone in memory.
Zone 1
Bar
(0 to 9)
Zone 2
Patio
(0 to 9)
Zone 3
Room 1
(0 to 9)
Zone 4
Room 2
(0 to 9)
Zone 5
Room 3
(0 to 9)