background image

Chuphotic.User’s Manual English-27.MOON-i 850-1600VA.Rev1.40/2019

AFTER SHIPMENT FROM THE FACTORY THE BATTERY
NEEDS RECHARGING. IF NOT USED FOR A LONG PERIOD
OF TIME, THE BATTERY WILL START SELF-DISCHARGING,
WHICH MAY RESRLT IN A SHORT SERVICE LIFE OF THE
BATTERY OR MAY EVEN CAUSE DAMAGE TO IT DURING
WARRANTY PERIOD. CARE SHOULD ALSO BE TAKEN TO
AVOID EXCESSIVE TEMPERATURE AROUND THE UPS,
WHICH COULD ALSO RESULT IN REDUCING SERVICE
LIFE OF THE BATTERY. TO ACHIEVE MAXIMUM SERVICE
LIFE FROM THE BATTERY THE ABOVE INSTRUCTIONS
SHOULD BE FOLLOWED.

Line Interactive UPS with LED

Line Interactive UPS with LED

CONNECT EQUIPMENT TO UPS

PLACE LOCATION THE UPS

Inspect items inside box:

  

  User’s Manual & Warranty Card
  UPS & Packaging Material
  Mains Power Cord
  Program & Communication(Option)

Examine the packing carton for damage. Notify your dealer immediately if damage
is observed. Store the packing in a safe place for possible future trans-shipment of
the UPS.

Avoid Direct Sulight.

Avoid Excessive Heat.

Avoid Excessive Humidity
or Liquids.

Avoid Excessive Dust.

IP20 Indoor Use.

The UPS is intended for indoor use only. Although your UPS is very rugged, its internal
components are not sealed from the environment. Kindly note the following.

Place location the UPS on a sturdy, dry surface in a wellventilated area away from 
direct sources of heat. Leave at least 100mm clearance all around the UPS to provide 
adequate ventilation.

CONNECT UPS TO POWER LINE

Connect the Power Cord, to a verified grounded 3-wire receptacle. Do not power the UPS
using a surge suppressor or power strip. The utility power Turn ON.

IP20

UPS INDICATORS AND CONTROLS

Product contains voltages, which are potentially hazardous. 
Qualified service personnel should perform all repairs.
Do not try to open the cover and to service the system yourself, on user 
serviceable parts inside.
Refer servicing to qualified service personnel only and warranty Condition
Product has its own internal energy source (battery). 
Outlet receptacles may be Hot even when the product is not connected 
to an AC supply.
In case of fire risky, please change the Fuse with the same kind and same 
rate or Reset breaker.
Product is intended for indoor use only. 
Kindly note to avoid excessive heat, dust, humidity

CAUTION AND WARNING

i

Enable the UPS by turning on the Power ON/OFF switch, which is situated on the
front panel.
The UPS is now ready to use. Switch on your equipment and you are ready to function.

BATTERY MAINTENANCE / BATTERY CHARGING

                    ON / OFF SWITCH

                    Turn ON this button to supply power to the 
                     UPS outlets. To switch off power to the UPS 
                    outlets 
                    Turn OFF the switch. This switch is 
                   situated on the front panel of the UPS.

BACKUP INDICATOR
(Red LED continuous bright)

The buzzer beeps every 8 seconds. 
The battery is powering the UPS outlets. 
The expected runtime for a typical personal
computer (PC) is about 10 to 40 minutes.

LOW BATTERY INDICATION
(Red LED continuous bright)

The buzzer beeps fast whenever the 
battery is near the end of its runtime. 
Promptly save your data and exit all 
applications and shutdown the operating 
system.

OVERLOAD INDICATION

The Yellow LED flashes, with continuous
beeping. UPS protects itself at this time.
Please move some load.

                    AC NORMAL INDICATOR
                    (Green LED continuous)

                    The UPS is supplying conditioned 
                    utility power to its outlets.

UPS
BATTERY

OVERLOAD
PROTECTION

AUTOMATIC
VOLTAGE
REGULATION

AC SURGE
PROTECTION

Buck-2Boost

FEATURE

FEATURE

Connect the Power Cord, to a verified grounded 3-wire receptacle. Do not power
the UPS using a surge suppressor or power strip. The utility power Turn ON.
(UPS Plug 3 Outlet, No Backup for Printer 1 Outlet)

i

Pb

CAUTION :

BEFORE INSTALLATION & OPERATION

Do not connect a surge suppressor,
power strip, or extension cord to the
UPS outlet.

Connect a Laser Printer or any 
non-computer peripherals to UPS
outlets.

Laser Printer

CB 7A/250V

Press to Reset

AC INPUT

OUTPUT UPS

OUTPUT UPS

In

TEL/ADSL

Out

CB 7A/250V

Press to Reset

OUTPUT UPS

OUTPUT UPS

AC INPUT

In

TEL/ADSL

Out

CB 7A/250V

Press to Reset

OUTPUT UPS

OUTPUT UPS

AC INPUT

In

TEL/ADSL

Out

CB 7A/250V

Press to Reset

AC INPUT

OUTPUT UPS

OUTPUT UPS

CB 7A/250V

Press to Reset

AC INPUT

OUTPUT UPS

OUTPUT UPS

In

TEL/ADSL

Out

In

TEL/ADSL

Out