INSTALLING THE DRIVE ARMS

Release the drive. Push the released drive onto the fittings and secure it by using the supplied bolts and rings.

WIRING

The 4-pole connecting cable is approx. 80 cm long and is laid in a curve to the controller or a watertight distribution box located above ground. An
approved cable is permanently installed from the distribution box onwards. The capacitor can be connected inside the distribution box or in the
controller.

Connection: Connect the capacitor across terminals CL and OP. CL and COM produce rotation direction A. OP and COM produce reversed direction
of rotation. 

Always remember to earth the installation.

MAINTENANCE WORK

The drive mechanism is maintenance free. Check that the gate fittings and the drive mechanism are securely fixed at regular intervals (monthly).
Release the drive and check that the gate functions properly. Unless the gate runs smoothly it will not operate correctly with the drive mechanism. The
drive cannot eliminate the problems caused by a gate that does not work satisfactorily.

CENTRAL UNIT
it's suggested to connect the central unit as last connection 
See the user manual of the central unit (ex. PCM20).

ELECTRONIC CONTROL

The control board should be the last item to be connected, i.e. mounting the motors, laying the necessary cable and fitting light barriers or contact
strips. If installation is to be performed in a permanent location, a means of disconnecting the equipment from the mains supply with a contact
clearance of at least 3 mm is needed (master switch).
Please note: in these instructions, relay contacts are designated NC (normal closed) or NO (normal open).

• NC contacts are closed and open
• NO contacts are open and close

Humidity and water will destroy the control board. Always make sure that water, humidity and condensation cannot enter the control box. It is
vitally important that all openings and cable glands are sealed so that they are watertight. 

Materials required (details vary depending on particular application)

• Distribution box
• Buried cable, at least 1.5 mm

2

• Buried cable, at least 0.5mm

2

• Screws
• Wall plugs

ELECTRICAL INSTALLATION

Installing the electronic control board: the motor control board is a microprocessor-controlled electronic appliance featuring state-of-the-art
technology. It is equipped with all the connecting options and functions needed to guarantee safe operation. An overview of the wiring plan is
shown in fig. 12D. The control box incorporating the motor control board should be installed with the cable intakes pointing downwards fig. 12A. It
should not be continuously exposed to direct sunlight. The electronic equipment enables the pull and push forces to be set with great accuracy. If
installed and set correctly, the gate/door can be stopped manually. When in motion, the gate/door can be stopped at any time by operating the
remote control, the push-button or the key-operated switch.
The gate/door wing must be fitted with a robust end stop for the 'OPEN' and 'CLOSED' positions as the gate/door drive has no limit switches. 
Current distribution: the cable leading from the drive arm must be laid in a standard watertight distribution box. A permanently installed cable can
be laid from the distribution box to the control unit. It is often possible to wire the drive, which is fixed beside the control unit directly to the box.
Never install distribution boxes underground.

Summary of Contents for ECO300

Page 1: ...ECO300 230Vac geared motor for 2 5m hinged gate ECO400 230Vac geared motor for 3 5m hinged gate Installation Manual...

Page 2: ...ease remove any locks fitted to the gate in order to prevent damage to the gate It is important to make sure that the gate always runs smoothly Gates which stick or jam must be repaired immediately Em...

Page 3: ...down to the switch on temperature The outdoor temperature and the gate are important parameters that affect the actual operating time INSTALLATION CHECKLIST PREPARATIONS Check the carton contents and...

Page 4: ...ects the fittings and gate to extreme stresses Different opening angles cause one motor to reach its destination first but continues to run thereby forcing the gate up against the gate stop until the...

Page 5: ...be custom made if the gate hinges are fitted on the posts appropriately it is possible to influence dimensions A and B Before the final mounting dimensions are determined you should always check whet...

Page 6: ...tances For steel gates fixings should be welded on or through bolted When through bolting the gate use large washers or a plate on the other side The drive mechanism exerts an extremely high force on...

Page 7: ...signated NC normal closed or NO normal open NC contacts are closed and open NO contacts are open and close Humidity and water will destroy the control board Always make sure that water humidity and co...

Page 8: ...C 6 Sede legale comm ed amm va Via Caserta al Bravo 218 80144 NAPOLI Tel 0039 081 705 09 12 pbx Fax 0039 081 705 01 25 e mail info hiltron it Declaration of conformity to the Standards of the Council...

Reviews: