1.

GENERAL WARNING

1.1

PLEASE READ BEFORE USING THIS MANUAL

• 

This manual is part of the product and should be kept near the instrument for easy and quick reference.

• 

The instrument shall not be used for purposes different from those described hereunder. It cannot be
used as a safety device.

• 

Check the application limits before proceeding.

1.2

 SAFETY PRECAUTIONS

• 

Check the supply voltage is correct before connecting the instrument.

• 

Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden
temperature changes with high atmospheric humidity to prevent  formation of condensation

• 

Warning: disconnect all electrical connections before any kind of maintenance.

• 

Fit the probe where it is not accessible by the End User. The instrument must not be opened.

• 

In case of failure or faulty operation send the instrument back to the distributor or to “Dixell s.r.l.” (see
address) with a detailed description of the fault.

• 

Consider the maximum current which can be applied to each relay (see Technical Data).

• 

Ensure that the wires for probes, loads and the power supply are separated and far enough from each
other, without crossing or intertwining.

• 

In case of applications in industrial environments, the use of mains filters (our mod. FT1) in parallel with
inductive loads could be useful.

2.

GENERAL DESCRIPTION

Models  XW270L and XW271L38x185 mm format, are microprocessor based controllers suitable for
applications on medium or low temperature refrigerating units. They are provided with six relay outputs to
control compressor, defrost - which can be either electrical or hot gas  - the evaporator fans, the lights, the
alarm and an auxiliary output. In XW271L the auxiliary output is configured as anti-condensing heater.
They are also provided with three NTC probe inputs, one for temperature control, one to control the defrost end
temperature of the evaporator and the third, optional, for the display. There are two digital inputs (free contact)
for the door switch and configurable by parameter.
The standard TTL output allows the user to connect, by means of a TTL/RS485 external module, a ModBUS-
RTU 
compatible monitoring system and to programme the parameter list with the “Hot Key”.
An optional output for remote display “XW-REP” is available.

3.

CONTROLLING LOADS

3.1 THE COMPRESSOR

The regulation is performed according to the temperature measured by the thermostat probe with a positive
differential from the set point: if the temperature increases and reaches set point plus differential the
compressor is started and then turned off when the temperature reaches the set point value again.
In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters
COn” and “COF”.

3.2 FAST FREEZING

When defrost is not in progress, it can be activated the keypad by holding the 

X

X

 key pressed for about 3

seconds. The compressor operates in continuous mode for the time set through the “CCt” parameter. The cycle
can be terminated before the end of the set time using the same activation key, 

X

X

 for about 3 seconds.

3.3 DEFROST

Three defrost modes are available through the “tdF” parameter: defrost with electrical heater, hot gas or
thermostatic defrost. The defrost interval is control by means of parameter “EdF”: (EdF=in) the defrost is made
every “IdF” time, (EdF=Sd) the interval “IdF” is calculate through Smart Defrost algorithm (only when the
compressor is ON and the evaporator temperature is bigger than “SdF” parameter).
At the end of defrost the drip time is controlled through the “Fdt” parameter.

3.4 CONTROL OF EVAPORATOR FANS

The fan control mode is selected by means of the “FnC” parameter:
FnC=C-n  fans will switch ON and OFF with the compressor and not run during defrost:;
FnC=C-y  fans will run continuously, but not during defrost
After defrost, there is a timed fan delay allowing for drip time, set by means of the “Fnd” parameter.
FnC=O-n  fans will switch ON and OFF with the compressor and run during defrost;
FnC=O-y  fans will run continuously also during defrost

An additional parameter “FSt” provides the setting of temperature, detected by the evaporator probe, above
which the fans are always OFF. This can be used to make sure circulation of air only if his temperature is lower
than set in “FSt”.

3.5 AUXILIARY OUTPUT

The auxiliary output is switch ON and OFF by means of the corresponding button on the keyboard.
The auxiliary output of the XW271L model controls the anti-condensing heater and it is automatically activated
if the room temperature is lower than the “SAA” parameter.

4.

KEYBOARD

To display and modify target set point; in programming mode it selects a parameter or confirm an
operation.
By holding it pressed for 3s when max or min temperature is displayed it will be erased.

To see the max. stored temperature; in programming mode it browses the parameter codes or
increases the displayed value. By holding it pressed for 3s the fast freezing  cycle is started.

To see the min stored temperature; in programming mode it browses the parameter codes or
decreases the displayed value.

By holding it pressed for 3s the defrost is started.

Switch ON and OFF the cold room light.

By holding it pressed for 3s Energy Saving function is started or stopped.

For XW270L model. Switch ON and OFF the auxiliary output.

For XW271L model. Switch ON and OFF the anti-condensing heater output.

Switch ON and OFF the instrument.

KEY COMBINATIONS

 

To lock and unlock the keyboard.

 

To enter the programming mode.

 

To exit the programming mode.

4.1 USE OF LEDS

Each LED function is described in the following table.

LED

MODE

Function

ON

The compressor is running

FLASHING

- Programming Phase (flashing with LED 

)

- Anti-short cycle delay enabled

ON

The fan is running

FLASHING

Programming Phase (flashing with LED 

)

ON

The defrost is enabled

FLASHING

Drip time in progress

ON

The Fast Freezing cycle is enabled

ON

- ALARM signal
- In “Pr2” indicates that the parameter is also present in “Pr1”

ON

(Present only in ’XW271L)
The Anti-condensing heater relay (Aux)  is ON.

Function of the LEDs placed on the left top side of buttons:

BUTTON

MODE

FUNCTION

SET

FLASHING

The Set point is displayed and it can be modified

SET

FAST FLASHING

The Energy Saving is enabled

DEFROST

ON

The Manual Defrost is activated

ENERGY SAVING

ON

The Energy Saving is enabled

LIGHT

ON

The Light is ON

AUX

ON

The Auxiliary output is ON (XW270L)

HEATER

ON

The Anti-condensing heater is ON (XW271L)

ON/OFF

ON

The instrument is OFF

4.2 HOW TO SEE THE MIN TEMPERATURE

1. 

Press and release the 

W

W

 key.

2. 

The “Lo” message will be displayed followed by the minimum temperature recorded.

3.

By pressing the 

W

W

 key or waiting for 5s the normal display will be restored.

4.3 HOW TO SEE THE MAX TEMPERATURE

1. 

Press and release the 

X

X

 key.

2. 

The “Hi” message will be displayed followed by the maximum  temperature recorded.

3.

By pressing the 

X

X

 key or waiting for 5s the normal display will be restored.

4.4 HOW TO RESET THE MAX AND MIN TEMPERATURE RECORDED

To reset the stored temperature, when max or min temperature is displayed :
1. 

Press SET key until “rST” label starts blinking.

N.B. After the installation RESET the temperature stored .

HOW TO SEE AND MODIFY THE SET POINT

1.

Push and immediately release the SET key: the display will show the Set point value;

2.

The SET LED start blinking;

3.

To change the Set value push the 

X

X

or 

W

W

 arrows within 10s.

4.

To memorise the new set point value push the SET key again or wait 10s.

Summary of Contents for CIAO GEL 12

Page 1: ...ICE CREAM DISPLAY CABINET CIAO series Maintenance And Use Manual CIAM SPA Viale dei Pini 9 Petrignano d Assisi PG Italy tel 075 80161 Fax 075 8016215 http www ciamgroup it e mail info ciamgroup it...

Page 2: ...freezers and ice machines For ETL marked cabinet UL471 CAN CSA C22 2 No 120 M91 NSF ANSI 7 2009 1 4 RESPONSIBILITY CIAM spa declines any responsibility relevant to damages on persons animals and or p...

Page 3: ...cle Refrigerating gas R 404A Glasses Heated side glasses hetaed front glass Standard internal compressor Type Hermetic single phase No 1 1 1 Nominal power W 600 725 2 x 560 Power current of display ca...

Page 4: ...ong stock have not to be ascribed to the manufacturer 5 4 DISPLAY CABINET POSITION The refrigerated display cabinet needs particular environmental conditions in order to offer the right performance so...

Page 5: ...the choice of piping diameter and insulation thickness has to be taken by specialised technical personnel who know specific parameters The choice of piping diameter and insulation thickness has to be...

Page 6: ...se the display cabinet has a dipper well it is necessary make the connection of its water outlet with the main water drain outlet besides it is necessary set a load water tube to the dipper well to th...

Page 7: ...a wet cloth weekly Additional defrost Under particular conditions of temperature and humidity the frost that normally forms on the evaporator and fans might increase in volume so leading to a faulty f...

Page 8: ...evaporator blocked by frost Verify the efficiency of the gasket seal relatively to the glass superstructure Verify that the display area is not crossed by draughts Verify that backsliders or night bl...

Page 9: ...ronics Replace digital thermostat Defrost water missing Water drain pipes are blocked Remove the obstacle Defrost cycle is not efficient Verify the efficiency of control panel slave module sensor sole...

Page 10: ...LEMENT OUTLET AIR HEATING ELEMENT REAR GLASS HEATING ELEMENT INTERNAL GLASS HEATING ELEMENT FRONT GLASS UPPER FRAME HEATING ELEMENT FRONT GLASS LATERAL LOWER FRAME HEATING ELEMENT FRONT GLASS LATERAL...

Page 11: ......

Page 12: ...L OF EVAPORATOR FANS The fan control mode is selected by means of the FnC parameter FnC C n fans will switch ON and OFF with the compressor and not run during defrost FnC C y fans will run continuousl...

Page 13: ...Remote display select which probe is displayed by the remote display XW REP P1 Thermostat probe P2 Evaporator probe P3 auxiliary probe 1r2 difference between P1 and P2 P1 P2 DEFROST tdF Defrost type...

Page 14: ...ore signalling the BAL alarm message The relay outputs are switched OFF The alarm will stop as soon as the digital input is de activated CONFIGURABLE INPUT PRESSURE SWITCH PAL If during the interval t...

Page 15: ...Power supply 230Vac or 110Vac 10 Power absorption 7VA max Display 3 digits red LED 14 2 mm high Inputs 3 NTC probes Digital inputs 2 free voltage Relay outputs Total current on loads MAX 20A compresso...