9. CONNECTIONS
Pay close attention to the correct sizing of the power and signal conductors. For installations
requiring long cable paths, the sections of the individual conductors in the shielded cable must
be appropriately sized.
The power cable cross-section must be calculated based on the length of the section and the
type of NEWTON-L used. The cross-section size of conductors connected to Alarm and Tamper
contacts depends on the model and on the absorption of the central control unit used.
Please see the table below, valid for single modules (transmitter only or receiver only, without
thermostat resistances).
10. POWER SUPPLY WIRE CROSS-SECTION TABLE,
FOR EACH OPTIC
Cross-section and
diameter of power supply
wires at 13.8Vdc
0.75 mm
2
1.5 mm
2
2.5 mm
2
Distance (max)
400 mt
800 mt
1,300 mt
With regards to connection type, please see specific instructions for the transmitter and
receiver.
Connect Alarm and Tamper outputs to a suitable alarm control unit.
11. ADDITIONAL NEWTON ALIM POWER PACK (optional)
If connections are too long, it is advisable to use an additional NEWTON ALIM power pack,
which is equipped with an extra power output, in addition to a 13.8 Vdc output, for demisting
thermostat resistances and connections for any backup battery.
The maximum overall current delivered by NEWTON ALIM is 1.5 A. This current must be
shared among the sensors, thermostat resistances and, if present, the battery.
The connection between the power pack and the 230 V~ network must be prepared with
suitable conductors, as per requirements and regulations in force.
It must also be prepared through an appropriate switching device with the following
characteristics:
- Two-pole with minimum distance between contacts of 3 mm
- fitted in the fixed system
- easily accessible
NEWTON ALIM can also be used with installation inside TOWER HT (TX and RX) columns.
In any case, you must scrupulously comply with the instructions contained in the laws
and regulations in force relating to fixed installations of equipment permanently
connected to the mains as in Ministerial Decree 37/08 and CEI 64-8 regulations.