ERMO 482X3
PRO
RECEIVER JUMPERS
Symbol
Function
Default
Jp1
Leds OFF from D8 to D13 (Jp1 position 1/2 = Leds ON)
ON
Jp2
RS 485 Line termination (Jp2 position 2/3 line terminated)
OFF
RECEIVER LEDS
Symbol
Function
Default
D11
Fault indi Alignment and setting functions
ON
D10
Tamper indi Alignment and setting functions
ON
D8
Alarm indi Alignment and setting functions
ON
D12
Alignment and setting functions
OFF
D13
Alignment and setting functions
OFF
D35
Main presence indication
ON
D36
Transmission communication indication
-
D37
Reception communication indication
-
SET
–UP BUTTON FOR ALIGNEMENT AND SETTING
Symbol
Function
S2
Button to accept data in alignment operation and to write parameter in
setting operations
RECEIVER FUNCTION SWITCH SW1
Symbol
Function
SW1
16 positions functions rotary switch
:
Position 1 = Barrier alignment
Position 2 = acquisition, of the installation values (Channel number and
AGC Voltage)
Position 3 = Prealarm thresholds Read/Write
Position 4 = Alarm thresholds Read/Write + Walk-Test
Position 5 = Masking thresholds Read/Write
Position 6 = Upper Prealarm thresholds Read/Write (FSTD)
Position 7 = Upper Alarm thresholds Read/Write (FSTD)
Position 8 = Barrier number Read/Write
Position 9 = Monitor thresholds Read/Write
Position A = Upper Monitor thresholds Read/Write
Position B = Battery Efficiency Test Read/Write
Position C = Save Prealarm Event
Position D = Not Used
Position E = Not Used
Position F = Balanced Line Active/Inactive
Position 0 = Alignment procedures ending
PARAMETERS AND BARRIER NUMBER READING AND SETTING
SWITCHES SW2- SW3
Symbol
Function
SW2
Decimal rotary switch to read or to set parameters during the alignment
operations (units column)
SW3
Decimal rotary switch to read or to set parameters during the alignment
operations (tens column)