CIAS Elettronica S.r.l.
Ed 1.1
Installation Manual
Page
49
of
51
Sioux Pro 2
With this solution, the following cable is required:
-
Cable between SiouxPro2-Line and distribution box
SiouxPro2-Line Line 1 or 2
Junction Box
Terminal
Terminal function
Wires Colour
Junction Box Functions
1
Power supply 27,6 Vcc
Green
Power supply 27,6 Vcc
1
Power supply 27,6 Vcc
White/Blue
Power supply 27,6 Vcc
2
GND
White/Orange
GND
2
GND
Orange
GND
2
GND
White/Green
GND
2
GND
Blue
GND
3
RS485 - High Line LH
Brown
RS485
– High Line LH
4
RS485 - Low Line LO
White/Brown
RS485
– Low Line LO
5
Shield
Shield
Shield
REMARKS:
-
Connect White/Orange, Orange, White/Green and Blue wires together, to terminal 2
(GND) of the SiouxPro2-Line terminal block
-
Connect Green and White/Blue wires together, to terminal 1 (27,6 Vcc) of the
SiouxPro2-Line terminal block
-
Cable between junction box and first Sioux-Slave-Pro2
REMARK
Using only precabled cable, check that colors correspond to numbering of
RJ45 connector’s pin
Pin
RJ45
1
st
Slave-Pro2 Connector
Functions
Wires Colour
Functions Junction box
1
GND
White/Orange
GND
2
GND
Orange
GND
3
GND
White/Green
GND
4
GND
Blue
GND
5
Power supply 27,6 Vcc
White/Blue
Power supply 27,6 Vcc
6
Power supply 3.3 Vcc
Green
Do not connect
7
RS485 - Low Line LO
White/Brown
RS485 - Low Line LO
8
RS485 - High Line LH
Brown
RS485 - High Line LH
Shield
Shield
Shield