8 Maintenance
8.1 Maintenance
Clean the hot air iron once a week thanks to a soft dust.
KEEP IN MIND A CLEAN MACHINE WORKS PROPERLY.
8.2 Replacing heating element
1.
Loosen the 3 screws that secure the hot air gun handle. The heating element is
located in the middle part of the hot air gun.
2.
Slide off the plastic tube.
3.
Disconnect the ground wire sleeve.
4.
The Quartz glass and heat insulation are installed inside the pipe. Loosen the cable and
remove the heating element.
5.
Insert the new heating element and reconnect the terminal. Be careful not to rub or touch
together the heating element wire.
6.
Reconnect the ground wire after replacing the heating element.
7.
Re-assemble the handle.