8.3 Basic troubleshooting guide
PROBLEM 1: THE UNIT HAS NO POWER
1.
Check if the unit is switched ON.
2.
Check the fuse. Replace with the same type if fuse is blown.
3.
Check the power cord and make sure there are no disconnections.
4.
Verify that the unit is properly connected to the power source.
PROBLEM 2: TEMPERATURE DISPLAY IS ALWAYS ABOVE 500°C
Description:
Constant display of above 500°C temperature from the panel then displays
a blinking "OFF" on both sides of the panel after a few minutes
SOLUTION:
The thermal sensor may be broken and needs to be replaced.
PROBLEM 3: ACTUAL AIR TEMPERATURE IS NOT INCREASING
Description:
Actual temperature reading is not increasing or decreasing based
on desired level (set temperature). The panel will then display a blinking "OFF" on both
sides afterwards.
SOLUTION:
The heating element may be broken and needs to be replaced.
PROBLEM 4: BANNER OR PRODUCT NAME IS ALWAYS SCROLLING -THE UNIT IS NOT
USABLE
Description:
The product name is just always scrolling from the digital panel, rendering the
device unusable.
SOLUTION:
Try to press "Reset" from the panel. Note that resetting the device will also
reset all previously defined configurations. If the problem persists, contact the vendor.