SERVICE MANUAL
Transmig 165
ST
Transmig 165
ST
Manual 0-5442 3-1 INSTALLATION
SERVICE MANUAL
Transmig 165
ST
Transmig 165
ST
SECTION 3:
INSTALLATION
G. The enclosure design of this power source meets
the requirements of IP23S as outlined in AS60529.
This provides adequate protection against solid
objects (greater than 12mm), and direct protection
from vertical drops. Under no circumstances
should the unit be operated or connected in a
micro environment that will exceed the stated
conditions. For further information please refer
to AS 60529.
H. Precautions must be taken against the power
source toppling over. The power source must
be located on a suitable horizontal surface in the
upright position when in use.
3.03 Ventilation
Since the inhalation of welding fumes can be harmful,
ensure that the welding area is effectively ventilated.
3.04 Mains Supply Voltage
Requirements
The Mains supply voltage should be within ± 15%
of the rated mains supply voltage. Too low a voltage
may cause poor welding performance. Too high a
supply voltage will cause components to overheat
and possibly fail.
The Welding Power Source must be:
• Correctly installed, if necessary, by a qualified
electrician.
• Correctly earthed (electrically) in accordance
with local regulations.
• Connected to the correct size power point and
fuse as per the Specifications on page 2-5.
!
WARNING
Any electrical work must be carried out by
a qualified Electrical Tradesperson.
3.01 Environment
These units are designed for use in environments with
increased hazard of electric shock as outlined in AS
60974.1 and AS 1674.2. Additional safety precautions
may be required when using unit in an environment
with increased hazard of electric shock. Please refer to
relevant local standards for further information prior
to using in such areas.
A. Examples of environments with increased hazard
of electric shock are:
1. In locations in which freedom of movement
is restricted, so that the operator is forced
to perform the work in a cramped (kneeling,
sitting or lying) position with physical contact
with conductive parts.
2. In locations which are fully or partially limited
by conductive elements, and in which there
is a high risk of unavoidable or accidental
contact by the operator.
3. In wet or damp hot locations where humidity
or perspiration considerable reduces the
skin resistance of the human body and the
insulation properties of accessories.
B. Environments with increased hazard of electric
shock do not include places where electrically
conductive parts in the near vicinity of the
operator, which can cause increased hazard, have
been insulated.
3.02 Location
Be sure to locate the welder according to the following
guidelines:
A. In areas, free from moisture and dust.
B. Ambient temperature between 0° C to 40° C.
C. In areas, free from oil, steam and corrosive gases.
D. In areas, not subjected to abnormal vibration or
shock.
E. In areas, not exposed to direct sunlight or rain.
F. Place at a distance of 300mm or more from walls
or similar that could restrict natural air flow for
cooling.
Summary of Contents for Transmig 165ST
Page 16: ...SERVICE MANUAL Transmig 165ST Transmig 165ST GENERAL INFORMATION 1 10 Manual 0 5442 Notes ...
Page 32: ...OPERATION 4 6 Manual 0 5442 SERVICE MANUAL Transmig 165ST Transmig 165ST Notes ...
Page 84: ...SERVICE MANUAL Transmig 165ST Transmig 165ST THEORY OF OPERATION 9 2 Manual 0 5442 Notes ...
Page 120: ...SERVICE MANUAL Transmig 165ST Transmig 165ST ASSEMBLY PROCEDURE 12 8 Manual 0 5442 Notes ...
Page 125: ...SERVICE MANUAL Transmig 165ST Transmig 165ST This Page Intentionally Blank ...