SERVICE MANUAL
Transmig 165
ST
Transmig 165
ST
SERVICE MANUAL
Transmig 165
ST
Transmig 165
ST
TIG (GTAW) WELDING 6-4 Manual 0-5442
6.02 Setup for TIG (GTAW) Welding
A. Connect the TIG Torch to the negative welding terminal (-). Welding current flows from the power source
via Dinse terminals. It is essential, however, that the male plug is inserted and turned securely to achieve
a sound electrical connection.
B. Switch the Power Source On/Off switch located on the rear of the Power Source to the On position and
ensure the Power indicator on the Front Panel is illuminated.
C. Select Lift TIG mode with the process selection control (refer to Section 4.02.11 for further information).
D. Connect the work lead to the positive welding terminal (+). Welding current flows from the Power Source
via Dinse terminals. It is essential, however, that the male plug is inserted and turned securely to achieve
a sound electrical connection.
E. Fit the welding grade shielding gas regulator/flowmeter to the shielding gas cylinder (refer to Section 6.01)
then connect the shielding gas hose from the TIG torch to the regulator/flowmeter outlet. Note that the TIG
torch shielding gas hose is connected directly to the regulator/flowmeter. Before turning on shielding gas
check that all fittings are tight and the gas valve on the TIG torch is turned off. The power source is not
fitted with a shielding gas solenoid to control the gas flow in TIG mode therefore the TIG torch will require
a gas valve.( Refer to Section 2.11 for optional TIG Torches). Before commencing to TIG weld open TIG
torch gas valve to allow sufficient shielding gas flow when welding. Refer to Section 6.03 for recommended
Shielding Gas flow rates and other TIG Welding information.
!
WARNING
Before connecting the work clamp to the work and inserting the electrode in the TIG Torch make
sure the mains power supply is switched off.
!
WARNING
Secure the welding grade shielding gas cylinder in an upright position by chaining it to a stationary
support to prevent falling or tipping.
CAUTION
Remove any packaging material prior to use. Do not block the air vents at the front or rear of the
Welding Power Source.
Loose welding terminal connections can cause overheating and result in the male plug being fused
in the terminal.
See over page for Setup for Lift TIG (GTAW) Welding diagram.
Summary of Contents for Transmig 165ST
Page 16: ...SERVICE MANUAL Transmig 165ST Transmig 165ST GENERAL INFORMATION 1 10 Manual 0 5442 Notes ...
Page 32: ...OPERATION 4 6 Manual 0 5442 SERVICE MANUAL Transmig 165ST Transmig 165ST Notes ...
Page 84: ...SERVICE MANUAL Transmig 165ST Transmig 165ST THEORY OF OPERATION 9 2 Manual 0 5442 Notes ...
Page 120: ...SERVICE MANUAL Transmig 165ST Transmig 165ST ASSEMBLY PROCEDURE 12 8 Manual 0 5442 Notes ...
Page 125: ...SERVICE MANUAL Transmig 165ST Transmig 165ST This Page Intentionally Blank ...