33
BLITZ
5-1996
9
MIXTURE AGITATION
9
Inside the tank a hydraulic and a pneumatic circuit allows a double system of agitation. When using products with marked
foam effect, it is possible to exclude the pneumatic circuit by closing the piston cock on the tank. When opening it again,
check that the air outlet holes are not clogged.
Before beginning the treatment it is essential to agitate the mixture in the tank recycling its volume
for the time necessary to make it homogeneous.
-The agitation should take place with the pressure adjustment knob cocks (P5) and the piston cock
on the tank completely open.
-This operation is essential to obtain a uniform distribution of the active principle over the whole
vegetation surface to be treated.
In case of a short break in the treatment, keep the agitation running till it is re-started. In case of a long break, before
re-starting duly agitate the mixture left in the tank.
10
DISCHARGE OF THE HYDRAULIC CIRCUIT
10
- Stop the tractor and take the key out of the control panel.
- Wear protective clothing and accessories to avoid risks of contamination by contact
or inhalation of the mixture.
- Discharge the circuit in an area suitably prepared and adequately equipped for
collecting the washing liquid.
This operation is carried out by means of the 3-ways tap (P3):
1. remove the cap with chain while the lever is in position
"a"
.
2. turn the lever to position
"b"
.
At the end of discharge, screw the cap with chain back in and turn the lever to position “
a
”.
P3
UMAP008b
UMAP008b
P3