50
BLITZ
5-1996
e
. Immediately wash all elements contaminated during the treatment, promptly take off the contaminated protection
clothes and
discontinue the job if these cannot be replaced.
f.
Immediately clean the clogged jets.
Avoid using hard and sharpened tools in presence of calibrated holes.
g
. If wind increases, follow the instructions given in the preliminary operations (12.1.c).
h.
During the pauses, stop the water and take the key out of the control panel.
i
. Pay special attention to treatments near property boundaries, houses, waterways, roads or public paths.
12.4 - END OF TREATMENT - STORAGE
12.4.
1
- Daily
The operator must:
a
. Wash the machine externally before cleaning the circuit. The sequence of operations will allow possible residues of
water ro be eliminated from the ventilating guard and from the pipings which bring the air flow to the heads. These
operations must be done in a place where the waste water may be collected in a disposal pit.
b
. Clean the hydraulic circuit, washing the interior of the tank with a jet of clean water then spraying the same on the
field where treatment was done. If necessary, repeat this operation.
c
. Check the efficiency of the distribution device (spray head) and the cleanliness of the pulverization points (diffusers),
replacing them if they are damaged or in bad condition.
The cleaning of calibrated holes must not be done with hard or sharpened tools.
d
. Put the machine in a ventilated place, sheltered from rain and sun; the rays of the sun are the worst enemies of plastic
and rubber parts.
12.4.
2
- End of seasonal cycle
The operator must:
a
. Carry out most accurately the operations described at the end of daily treatments; the hydraulic circuit cleaning must
be done at least twice. Check that in no part of the circuit there is product residue.
b
. Completely empty the hydraulic circuit, paying special attention to the centrifugal pump.
Avoid using antifreeze solutions.
c
. Check the functionality of the components and structures of the machine. In case of negative results, ask for the
intervention of one of our after-sale service centers.
d
. Put the machine in a ventilated place, sheltered from rain, ice and rays of sun.
The use of detergent products for cleaning is allowed only following the norms in force. In merit,
the operator should get the necessary information from the competent authorities.