58
BLITZ
5-1996
16
REPAIRS ALLOWED
16
THE OPERATOR IS NOT ALLOWED TO CARRY OUT MODIFICATIONS ON THE ATOMIZER'S STRUC-
TURES OR IN ITS OPERATION. THIS WOULD MEAN THE IMMEDIATE LOSS OF ALL THE EXISTING
RIGHTS OF GUARANTEE AND WOULD FREE C.I.M.A. S.p.A. OF ANY CONSEQUENT RESPONSABILI-
TY.
16.1 - ASSEMBLYING THE PUMP CONTROL BELT
Stop the motor and take the ignition key out of the tractor control panel.
Remove the fan group protection guard by unscrewing the nut fixing it to the frame.
Unscrew the belt stretcher spring adjustment nut: the pump supporting plate is now free to rotate.
Introduce the belt into the pump pulley race and then into the race of the upper pulley, behind the release.
Reset the belt stretcher spring in in the prescribed tension condition.
Re-assemble the fan group protection guard.
UMAP009
1
ADJUSTMENT GROUP
FUSE CARRIER
COVER
UMAP053
ELECTRIC
CONTROL UNIT
FUSE
Stop the motor and take the
ingition key out of the tractor's
control panel.
1. Unscrew the fuse holding cover;
2. Replace the fuse and screw the cover again.
*
Fuse: 1,25 A with delay.
ALL OTHER TYPES OF REPAIRS MUST BE
CARRIED OUT AT A CIMA S.p.A. AFTER-
SALE SERVICE CENTER. C.I.M.A. S.p.A..
2
PROTECTION GUARD
UMAT006
UMAP025
PLATE
3
4
PUMP
V BELT
UMAT039
Accurately tighten the screws and the nut used for this operation.
16.2. - REPLACING THE FUSES OF THE ELECTRIC UNIT.
NUT