09-2008
Plus 42 - 45 - 50 - 55
29
5.3 - INSTALLATION OF REMOTE CONTROLS
5.3.1 - Manual 2-tap distributor - P9
00084
MOUNTING
BRACKET
MANUAL
DISTRIBUTOR
BAYONET
SUPPORT
P9
T4
T5
1 - Mount the securing bracket on the tractor
within the driver’s reach (if this is not already
present on the tractor).
2 -
Insert the distributor’s bayonet support in
the securing bracket.
3 - Connect the feeding pipe (T4)
4 - Connect the distribution piping (T5) al circuito
idraulico del dispositivo di distribuzione (te-
stata) montato sulla macchina (seguire le
istruzioni dello specifico libretto "uso-manu-
tenzione" che lo accompagna).
Position the distribution piping (T5)
and feed piping (T4) so as to avoid
the risk of suffering damage or
breakage during spraying. IT MAY
BE NEEDED TO SHORTEN THE PIPES.
IN CASE OF A PIPE BURST:
1 - Stop the tractor and remove the key from the
control panel.
2 - Close the 2 taps of distributor (P9).
3 - Move the 3-way cock (P6) lever to position “d”
4 - Repair or replace the broken pipes (for the elimination of these parts, please follow the current
regulations).
5.3.2 - Electrical control panel - E10
(for versions provided with)
1 - Fix the fastening bracket near to the driver (if not already available on the tractor).
2 - Insert the bayonet support of the control panel in the securing clamp.
3.
Connect the distribution piping (T5) to the hydraulic circuit of the distribution device (head) mounted
on the machine (follow the instructions of the specific “use and maintenance” book-let which is
supplied with it).
4.
Connect the feeding pipe (T4) with the electrical distributor (E9).
5 - Connect the power supply cable (W1) plugging it in the socket of the tractor (cigar-lighter socket).
Position the electrical cables (W1) and (W2) in such a way as to avoid risking their
being wrenched off during treatments. If necessary, use some securing clamps.
A sudden interruption of power will lock the 2 solenoid valves of the electrical
distributor (E9). Should this fault take place when they are in the open position, it
is necessary to:
- Stop the tractor and remove the key from the control panel.
- Position tap (P6) on "d".
- Restore the electric current.
Plus 42 - 45 - 50 - 55
09-2008
40
d
b
a
c
00104
350
300
250
200
150
100
50
50 Plus
2000
2000
00033
00971
b
c
a
P2
E10
00140
P6
c
a
P3
a
c
®
ON
Remote Control
H O
2
ON
OFF
OFF
* for the versions where is foreseen
d
b
a
c
P15 *
00093
P9
P5
00974
P6
*
00105
00245
00299
c
a
P12
*
00133