09-2008
Plus 42 - 45 - 50 - 55
31
6
DISTRIBUTION DEVICES
6
Every distribution device is supplied with its own USE AND MAINTENANCE booklet
that is, or will have to be, attached to this publication and will constitute one of its
integral parts.
The “Distribution devices –Operatio and maintenance instructions” manual both shows and describes
the wide range of the distribution devices (heads), to be employed on each sprayer in order to assure
a perfect covering, always answering to the real requirements of the culture to be treated. All the heads
can be very easily oriented and regulated, so to optimise the necessary covering.
Simple heads
Simple heads
Simple heads
Simple heads
Simple heads
00111
00117
Combined heads
Combined heads
Combined heads
Combined heads
Combined heads
00493
DELIVERY ON ONLY ONE SIDE
DELIVERY ON THE TWO SIDES
00495
00482
00122
00494
DELIVERY ON ONLY ONE SIDE
DELIVERY ON THE TWO SIDES
00163
00508
00509
Plus 42 - 45 - 50 - 55
09-2008
38
5b.
FILLING WITH MEDICINAL MIXTURES OR LIQUID PRODUCTS
5b1.Pour the medicinal mixture envisaged for every loading (together with the water possibly used
for the washing of product canisters and of the tools used in the preparation) into the main
filler(BP).
5b2. Close the main filler (BP) of the tank.
5b3.Engage the drive outlet (PTO) and take it to a speed of at least 500 RPM
5b4. Complete the filling with water and close the lid of the secondary filler (BS)
6. Move to the treatment place, keeping the Power Takeoff running rate at a minimum value of 500
r.p.m. during all the way.
FILLING DIRECTLY IN THE TREATMENT AREA:
7.
Disengage the drive outlet (PTO) and rest the sprayer on the ground.
Stop the tractor and remove the key from the control panel.
8. Ensure that the fan is stopped. Engage the fan to the servo amplifier as indicated at point 8.1, then
re-close the mobile protection cover.
Tighten the protection-securing screw properly.
9. Start the tractor.
10. Lift the unit. Engage the Power Takeoff and set it up to a running rate of at least 500 r.p.m.
, in order
to carry out a further agitation.
12. Regulate the operating pressure, by acting on the pressure regulator (P5) (or electric E5) with the
distributor, hand (P9) or electric (E9), open (DISTRIBUTION).
13. CARRY OUT THE TREATMENT (See the paragraph 11.3).
8.3 - FILLING WITH THE SPECIFIC PIPE
(optional device)
USE ONLY IF CONCURRED FROM THE LAWS OF THE COUNTRY WHERE THE SPRAYER
IS USED. Before utilisation, check the operation and proper sealing of the bottom-
drawing valve by pouring water in the piping.
THE PUMP MUST NEVER RUN DRY.
EXECUTION:
1. Disengage the fan, see point 8.1.a.
2. Close the 2-way distributor:
a. se manual (P9), set the levers in the horizontal position;
b. if electrical, position the latch switches (E10) on “OFF”.
3
.
Check that:
- P6: is open (lever on “a”);
- P12: is closed (lever on "c");
- P5, pressure regulator: is completely open for the unit’s first use, or on the already selected
position for the outstanding treatment or for the previous one.
4. Close the faucets (P2) (or P15) by positioning the lever on “c.”
5
.
Connect the filler piping to the pump.
6. Re-open the faucets (P2) (o P15) (lever on "a").
7. Immerse the filter with the bottom-drawing valve in the water to be loaded.