- 24 -
Unplugging a Clogged Hose
SEALING TIP
WAND
ACCESS PORT
WAND VALVE
SEALING HOSE VALVE
PRESSURE VALVE
STACK DIVERTER
(Propane units only)
2)
If the unit is not full of material, add material to lower the tank temperature enough so the
control box will fire the burner. Keep adding material until the cabinet temperature is
high enough to unplug the hose.
NOTE: Be sure to open the thermal regulating gate to the full open position. On
propane units, be sure the stack diverter is closed.
3)
If the unit is full, it may be necessary to open up the loading door and allow the material
to cool down. Turn the temperature control setting to 250º F. Allow the material to cool
down enough so that the burner will have to run for a period of time long enough to heat
the hose sufficiently. The actual time required will vary depending on how much material
and what type of material is left in the hose. Thermal regulating gate must be wide
open. On propane units, the stack diverter must be closed.
4)
If the unit is clogged and the above two procedures are not possible, it may be neces-
sary to use a back up hose. The clogged hose can then be connected and unplugged
the next time you start up with a cold material tank.
The above situations illustrate the importance of properly cleaning the hose after use. It also
shows the importance of returning the hose to the access port during times between use to
keep the material flowing freely through the hose.
Summary of Contents for MAGMA 110
Page 48: ... 48 Wiring Diagrams Refer to Individual Wiring Diagrams for Details ...
Page 49: ... 49 Wiring Diagrams Trailer Wiring Diagram ...
Page 50: ... 50 Engine and Burner Wiring Harness Wiring Diagrams ...
Page 51: ... 51 Wiring Diagrams Relay Panel ...
Page 52: ... 52 Wiring Diagrams Temperature Control Wiring Diagram ...
Page 53: ... 53 Wiring Diagrams Primary Control ...
Page 54: ... 54 Wiring Diagrams LOFA Engine Shutdown Heated Hose Generator ...
Page 59: ... 59 Plumbing System Parts List Dual Wand Single Wand ...
Page 75: ... 75 11 12 Miscellaneous Parts ...
Page 77: ... 77 ...
Page 78: ...2601 Niagara Lane Plymouth MN 55447 763 557 1982 800 328 3874 Fax 763 557 1971 ...