Filter noise attenuation-RFI 
(loss measured into a 50 ohm system) 

Approvals: 

Specifications:

 

 
Current rating:    

20 amps, fuse protected 

Input voltage: 

 

75-140 VAC 

Active Voltage Protect:      Below 90 or above 136 VAC 

Meter accuracy:   

±3 VAC  

Remote trigger voltage:      12 volts AC/DC  

Spike protect modes: 

Line to neutral, neutral to ground,  

 

 

 

line to  ground 

Clamping voltage: 

250v peak   (175 Volts RMS.) 

Response time:   

1 nanosecond 

Max surge current: 

58,500 amps 

Max spike energy: 

2880  joules  

Noise attenuation: 

 >25 dB @ 200 kHz 

 

 

 

 >60 dB @ 5 MHz 

RF pass thru loss:  

Less than 1 dB (below 800 MHz) 

Dimensions: 

 

1.75x19x8” (H<W<D), 12 Lb. 

Construction: 

 

UL approved components  

 

 

 

Mil spec glass epoxy circuit boards 

 

 

 

Steel chassis, zinc chromate plating 

 

 

 

Twin aluminum slide out lamp tube 

 

 

 

on Teflon bearings. 

Power consumption: 

Control circuits – 12 watts 

Fuses:   

 

Main – 15 Amps, 120/250V 

 

 

 

Sense– 250 ma., 120/250 V 

 
Safety information: 

UL, CSA, and Canadian UL app.  

 

 

 

COAXIAL SURGE PROTECT 

 
The PowerLight 2400 includes convenient “F” style 
connectors for hooking up satellite and cable TV.  This 
allows full surge protection to these often overlooked  
sources of possible lightning spikes.  This is a low loss 
pass-through connection. 
 
Simply connect the coaxial cable coming from the wall 
(or satellite dish) to the corresponding connector 
marked “IN.”  Connect an additional cord from “COAX 
OUT” directly  to the desired VCR, TV, or DSS Tuner.  
 

LIGHTNING AND SURGE PROTECTION 

 
The PowerLight 2400 will help protect all equipment 
plugged into its outlets from lightning strikes and power 
line surges.  If the lightning strikes a distant power line, 
the PowerLight 2400 will protect your equipment  
invisibly and harmlessly.  
  
In the unlikely event that lightning strikes your actual 
building or a location close to it, the PowerLight 2400 
will protect your equipment, but may sustain some 
minor damage to its internal fuses and MOV’s.  This 
will be indicated if the front panel PROTECT indicator 
is not on.  

If this is not lit

, have the unit inspected at a 

local repair shop, or return it to the factory for 
inspection and recalibration.  There is a nominal charge 
for refitting and recalibrating the PowerLight 2400. 
 
In extremely active lightning areas, we recommend the 
extra precaution of a whole house lightning protector, 
installed at the incoming breaker box for maximum 
protection.  Contact your local utility company or a 
licensed electrician for more details. 
 

CARE AND MAINTENANCE 

 
The PowerLight 2400 is manufactured from the finest 
components.  It will provide many years of flawless 
performance with little or no maintenance, aside from 
occasionally wiping the front panel with a mild glass 
cleaner.  Do not use harsh solvents as they may harm 
the finish.  Please do not open the sealed cabinet. There 
are no user serviceable parts inside. 
 

 

 

 
 

Thank you for choosing Cinepro.  

 

     Enjoy your new component. 

 