background image

3

 

Host Interface Setting   

FuzzyScan Scan Engine is designed to support RS232 Serial, USB HID and USB 
COM  Port  Emulation  interfaces.  Please  choose  RS232  or  USB  interface  cable 
before connecting the Scan Engine Evaluation Kit and host device. 
 
The default host interface of Evaluation Kit is USB COM Port Emulation. But for 
easy evaluation purpose, the host interface of Evaluation Kit has been preset to 
USB HID for your convenience. Please refer to following table and illustration to 
arrange the proper dip switch setting to get your desired host interface. 
 
 

Dip Switch 

RS232 

USB 

ON 

OFF 

ON 

OFF 

OFF 

ON 

OFF 

ON 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
Please  scan  the  corresponding  Host  Interface  Quick  Set  barcode  command  to 
complete the host interface setting after you finish the dip switch setting. 
 

If the USB COM Port Emulation interface is selected, you have to install the USB COM Port 

Emulation driver in your host system before using the Scan Engine. You can download the 

driver from the website 

www.cino.com.tw

 

RS-232 Serial 

USB 

Reviews: