background image

 

Chapter 5

  Defining Output Format 

 

5.6.1 EDIT A CONCATENATION OF BARCODES 

 

 

 

Edit Output Sequence 

 

1)

 

Read the barcode above to start editing a concatenation of barcodes. 

2)

 

Code Type setting – read the 

Hexadecimal Value

” barcode on page 264 for Code Type 

of the (first) barcode. For example, read “4” and “1” for Code 39. 

Code Type  Symbology 

Code Type  Symbology 

40 (@) 

ISBT 128 

 

 

41 (A) 

Code 39 

 

 

42 (B) 

Italian Pharmacode 

 

 

43 (C) 

N/A 

 

 

44 (D) 

Industrial 25 

64 (d) 

TLC-39 (TCIF Linked Code 39) 

45 (E) 

Interleaved 25 

65 (e) 

Trioptic Code 39 

46 (F) 

Matrix 25 

 

 

47 (G) 

Codabar (NW7) 

67 (g) 

Code 11 

48 (H) 

Code 93 

 

 

49 (I) 

Code 128 

 

 

4A (J) 

UPC-E0 / UPC-E1 

6A (j) 

Composite CC-C 

4B (K) 

UPC-E with Addon 2 

6B (k) 

PDF417 

4C (L) 

UPC-E with Addon 5 

6C (l) 

MicroPDF417 

4D (M) 

EAN-8 

6D (m) 

Data Matrix 

4E (N) 

EAN-8 with Addon 2 

6E (n) 

Maxicode 

4F (O) 

EAN-8 with Addon 5 

6F (o) 

QR Code 

50 (P) 

EAN-13 

70 (p) 

US Postnet 

51 (Q) 

EAN-13 with Addon 2 

71 (q) 

US Planet 

52 (R) 

EAN-13 with Addon 5 

72 (r) 

UK Postal 

53 (S) 

MSI 

73 (s) 

Japan Postal 

54 (T) 

N/A 

74 (t) 

Australian Postal 

55 (U) 

GS1-128 (EAN-128) 

75 (u) 

Dutch Postal 

56 (V) 

UPC-A 

76 (v) 

Composite CC-A/B 

57 (W) 

UPC-A with Addon 2 

77 (w) 

Macro PDF417 

58 (X) 

UPC-A with Addon 5 

78 (x) 

Macro MicroPDF417 

 

 

 

205

 

Update 

Summary of Contents for 2564MR

Page 1: ...2564MR Barcode Scanner Setup barcodes included Version 1 00...

Page 2: ...s in writing CIPHERLAB does not warrant that this document is error free No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electroni...

Page 3: ...n a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is sub...

Page 4: ...CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage 2 l utilisateur de...

Page 5: ...ices which are not originally sold or manufactured by CipherLab will void your warranty and may cause damage to human body or the product itself DO NOT disassemble incinerate or short circuit the batt...

Page 6: ...Version Date Notes 1 00 Jan 09 2017 Initial release...

Page 7: ...duct Highlights 7 Symbologies Supported 8 QUICK START 11 Enter Configuration Mode 13 Exit Configuration Mode 13 Default Settings 13 Save User Settings as Defaults 13 Restore User Defaults 14 Restore S...

Page 8: ...tive Barcodes 46 1 13 Picklist Mode 47 1 14 Mobile Phone Display Mode 47 1 15 Illumination Brightness 48 1 16 Serial Number Stamp 48 1 16 1 Separator between Serial Number Stamp and Data 48 1 17 2D De...

Page 9: ...81 2 5 1 Activate RS 232 Interface 81 2 5 2 Baud Rate 81 2 5 3 Data Bits 82 2 5 4 Parity 82 2 5 5 Stop Bit 83 2 5 6 Flow Control 83 2 5 7 Inter Character Delay 83 2 5 8 Inter Function Delay 84 2 5 9...

Page 10: ...23 4 5 Code 25 Chinese 25 124 4 6 Italian Pharmacode Code 32 125 4 7 Code 39 125 4 7 1 Verify Check Digit 126 4 7 2 Transmit Check Digit 126 4 7 3 Standard Full ASCII Code 39 126 4 7 4 Code Length Qua...

Page 11: ...155 4 19 4 Transmit Check Digit 156 4 20 Code 11 156 4 20 1 Verify Check Digit 156 4 20 2 Transmit Check Digit 157 4 20 3 Code Length Qualification 157 4 21 Composite Code 159 4 21 1 Composite CC A B...

Page 12: ...5 4 3 Clear Code ID Settings 195 5 5 Length Code 196 5 6 Multi Barcode Editor 203 5 6 1 Edit a Concatenation of Barcodes 205 5 6 2 Activate the Concatenation of Barcodes 206 5 7 Removal of Special Ch...

Page 13: ...nds 251 Example 253 BT Cradle Setup Barcodes Serial Commands 255 BT Cradle Serial Command and Equivalent Setup Barcodes 256 Example 257 KEYBOARD WEDGE TABLE 259 Key Type Status 260 Key Type 260 Key St...

Page 14: ...keep business running A new ordering option is provided for adapting a 2D scan engine to read both 1D and 2D barcodes Owing to the slim ergonomic design extremely low power consumption and powerful de...

Page 15: ...the battery into the battery compartment at the bottom of the scanner 2 Slide the battery latch to lock the battery in the compartment 3 Hold down the trigger about 2 seconds to turn on the scanner 4...

Page 16: ...Initialize Red solid Failed to establish a USB connection Red solid Blue flashing Serial command mode with USB Virtual COM or RS 232 wait 3 seconds for starting a serial command Red flashing Blue fla...

Page 17: ...2564MR Barcode Scanner User Guide Red flashing Enter Download Mode CHARGING THE BATTERY VIA THE CRADLE 4 Enter Setup...

Page 18: ...adle to your computer or notebook via the USB or RS 232 cable 4 Connect the power supply cord from the cradle to a proper power outlet Warning RS 232 USB interface both require connecting the power su...

Page 19: ...nded to charge the battery at room temperature 18 C to 25 C for optimal performance 1 Slide the battery smoothly until the latch rises to secure it 2 Connect the power supply cord to the charger 3 Con...

Page 20: ...iety of 2D symbologies Supports different scan modes including Aiming Mode and Multi Barcode ModeNote User feedback via LED indicator and beeper Beeping tone and duration programmable for Good Read 4...

Page 21: ...nabled GS1 128 EAN 128 Enabled ISBT 128 Enabled Code 2 of 5 Industrial 25 Enabled Interleaved 25 Enabled Matrix 25 Disabled Chinese 25 Disabled Code 3 of 9 Code 39 Enabled Italian Pharmacode Disabled...

Page 22: ...mposite CC C Disabled Composite TLC 39 Disabled Postal Code US Postnet Enabled US Planet Enabled UK Postal Enabled Japan Postal Enabled Australian Postal Enabled Dutch Postal Enabled USPS 4CB One Code...

Page 23: ...ter reading the barcode 3 Have the scanner read more setup barcodes Most of the setup barcodes are normal The scanner will respond with two beeps low high tone For special setup barcodes it requires r...

Page 24: ...up a WPAN Connection for details The connection between the scanners and the cradle is made easy and reliable Note If RS 232 USB Virtual COM or BT SPP is selected for output interface the host can di...

Page 25: ...CONFIGURATION MODE For the scanner to save settings and exit the configuration mode you must have it read the Update barcode which can be located at the bottom of almost every odd page of this manual...

Page 26: ...n to their customized values Restore User Defaults RESTORE SYSTEM DEFAULTS For the scanner to restore the factory defaults you must have it read the Restore System Defaults barcode This is a normal se...

Page 27: ...configured for interface Key Type and Key Status will then become applicable You may decide whether or not to change key status when Normal Key is selected for Key Type To complete the configuration...

Page 28: ...3 Read a Setup barcode For example The scanner will respond with two beeps low high tone if reading a normal setup barcode 4 Exit the Configuration Mode OR Same as for Enter the Configuration Mode 5 T...

Page 29: ...h two beeps low high tone if reading a normal setup barcode The scanner will respond with one short beep if reading a special setup barcode such as Max Length indicating the setup requires reading mor...

Page 30: ...arcodes When BT HID USB HID or Keyboard Wedge is configured for interface Key Type and Key Status will then become applicable You may decide whether or not to change key status when Normal Key is sele...

Page 31: ...Scanner Parameters List Page 1 List settings regarding Prefix Suffix and Length Code Setting 1 2 List Page 2 List settings regarding Prefix Suffix and Length Code Setting 2 2 List Page 3 List setting...

Page 32: ...t Page 16 List settings regarding Editing Format 4 1 2 List Page 17 List settings regarding Editing Format 4 2 2 List Page 18 List settings regarding Editing Format 5 1 2 List Page 19 List settings re...

Page 33: ...ding three setup barcodes for the command parameter 109952 to take effect Enter Setup List Page 3 Update 2 Now it requires only one read One Scan Setup Barcode for 109952 Note The scanner will restart...

Page 34: ...ill need to input the serial commands in sequence as follows underlining the digits is to make them more readable CipherLab101231109902109903109994 2D One Scan Setup Barcode for configuring suffix Com...

Page 35: ...V 800 mAh Li ion battery and it takes approximately 5 hours to charge the battery to full from the power adaptor However the charging time may vary by working condition For intensive data collection...

Page 36: ...ble 0 Disable By default the scanner stands by at full speed for 2 minutes after power on and before entering low speed mode If Power Saving isn t desired set it to 0 to disable it Read the setup barc...

Page 37: ...y scan mode other than Test Mode you can ignore Auto Power Off Ignoring Scan Mode Auto Power Off after 0 254 min 10 1 Read the barcode above to enable the scanner to automatically turn off at a specif...

Page 38: ...de b trying to connect to the host BT HID or BT SPP Master Mode c trying to connect to the cradle 2 If the scanner fails to connect within 2 minutes it becomes inactive to save power for the remaining...

Page 39: ...Pull down the trigger for about 2 seconds to turn it on again For BT HID the scanner resumes the connection with the host upon powering on again as long as the host application is running You will hea...

Page 40: ...on status and keep on reading barcodes until the buffer is full When transmit buffer is enabled If the scanner is out of range it will respond with two short beeps high low tone upon reading a barcode...

Page 41: ...er is in memory mode it means any real time connection established with host is disabled Enable Disable Warning No real time connection is allowed unless the memory mode is disabled Memory Data Delay...

Page 42: ...t will resume the previous WPAN connection with host temporarily Send Data Clear Data Confirm Even though data has been sent back to the host the flash memory is still occupied unless you erase the me...

Page 43: ...l with one long beep low tone Transmit buffer disabled with one long beep low tone Memory full in memory mode with two short beeps high low tone Green on off Good Read with one short beep high tone an...

Page 44: ...ging from 1 to 254 in units of 10 milliseconds Good Read LED Time out after 0 01 2 54 sec 40 ms 1 Read the barcode above to specify the time interval before the Good Read LED goes off 2 Read the Decim...

Page 45: ...Barcode Editor with green LED on off quickly Upon completion same as Good Read One long beep low tone Transmit buffer full with red LED on off quickly Transmit buffer disabled with red LED on off qui...

Page 46: ...2564MR Barcode Scanner User Guide Mute Minimum Volume Medium Volume Maximum Volume 34 Enter Setup...

Page 47: ...Chapter 1 Understanding the Barcode Scanner 1 4 2 GOOD READ BEEP Frequency 8 kHz 4 kHz 2 kHz 1 kHz Duration Shortest Shorter Longer Longest 35 Update...

Page 48: ...RM By default it will activate the beeper to give a warning when the battery charge gets low In order to prevent data loss you are advised to replace the battery immediately when you hear two short be...

Page 49: ...rcode Scanner 1 5 SEND NR TO HOST This feature only works when Keyboard Wedge or RS 232 is selected for output interface You may have the scanner send the NR string to the host to notify the No Read e...

Page 50: ...n Mode Start to Scan Stop Scanning Always Press trigger once Hold trigger Press trigger twice Release trigger Press trigger once Barcode being read Timeout Test mode Laser mode Auto Off mode Auto Powe...

Page 51: ...The scanner will start scanning once the trigger is pressed The scanning won t stop until 1 a barcode is decoded and 2 the pre set timeout expires Note Refer to Scanning Timeout Auto Off Mode 1 6 4 A...

Page 52: ...he Validate barcode on the same page to complete this setting 1 6 6 MULTI BARCODE MODE The scanner will be scanning as long as the trigger is held down capable of decoding one single barcode as well a...

Page 53: ...ght within range the scanner will be able to decode it It is suggested to seat it in the Auto Sense Stand for hands free operation Presentation Mode Low Light Enhancement Enabling Low Light Enhancemen...

Page 54: ...Auto Power Off mode Aiming mode Scanner Time out after 0 254 sec 10 1 Read the barcode above to specify the time interval before the scan engine times out 2 Read the Decimal Value barcode on page 263...

Page 55: ...s also referred to as the Blocking Time which is used to prevent the scanner from accidentally reading the same barcode twice when the scan mode is set to any of the following Auto Power Off mode Pres...

Page 56: ...tive successful decoding of the same barcode to make the reading valid The higher the reading security is that is the more redundancy the user selects the slower the reading speed gets It is obvious t...

Page 57: ...s and thus the slower the reading speed becomes You will have to compromise between reading security and decoding speed Note UPC EAN Addon 2 and Addon 5 must be enabled individually for this setting t...

Page 58: ...n automatically in Auto sense mode when you seat it in the stand connecting to the power socket By default this mechanism is disabled You have to enable it by having the scanner read the Enable barcod...

Page 59: ...st Mode enables the decoder to decode only the barcodes aligned at the center under the laser aiming pattern Enable Disable 1 14 MOBILE PHONE DISPLAY MODE By default this mode is disabled There is a b...

Page 60: ...ness level 3 Read the Validate barcode on the same page to complete the setting 1 16 SERIAL NUMBER STAMP Decide whether to add the device serial number in front of the data transmitted Add serial numb...

Page 61: ...effectiveness of the illumination decreases as the distance to the target increases Enable Disable 1 17 3 ILLUMINATION BRIGHTNESS Specify the illumination brightness level ranging from 1 to 10 for th...

Page 62: ...See the following sections for output interfaces supported 4 Have the scanner read the barcodes for related settings 5 Have the scanner read the Update barcode to exit the configuration mode 6 Turn on...

Page 63: ...er and the scanned data will be transmitted to the computer HID Settings Defaults Keyboard Type PCAT US Alphabets Layout Normal Digits Layout Normal Capital Lock Type Normal Capital Lock State Off Alp...

Page 64: ...the Decimal Value barcode on page 263 Refer to the table below for the number of desired keyboard type 3 Read the Validate barcode on the same page to complete this setting BT HID By default the keyb...

Page 65: ...r host you must have it read the Reset Connection barcode so that the current connection record will be cleared Then the scanner will restart itself automatically Go through the whole process in 3 2 3...

Page 66: ...s Transmission Numeric Key Alphabets Layout By default the alphabets layout is set to normal mode also known as the standard English layout Select French or German keyboard layout if necessary The sca...

Page 67: ...special characters French Keyboard Style AZERTY French layout see below for French Keyboard Style Select Upper Row for the Digits Layout setting for the lower row is for special characters German Keyb...

Page 68: ...s unavailable but required Capital Lock Type Setting In order to send the alphabets with correct case the scanner needs to know the status of Caps Lock on the keyboard Incorrect settings may result in...

Page 69: ...e scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted transmitted characters are exactly the same as in the barcode when case sensitive is selected for...

Page 70: ...ng Output Interface Digits Transmission By default the alphanumeric keypad is used for transmitting digits Select Numeric Keypad if you wish to use the keys on the numeric keypad Numeric Key Alphanume...

Page 71: ...m Kanji Transmission is disabled by default Enable disable scanner s Kanji Transmission by reading the following barcodes Enable Disable 2 1 4 INTER CHARACTER DELAY By default the inter character dela...

Page 72: ...1 Read the barcode above to specify the inter function delay 2 Read the Decimal Value barcode on page 263 for the desired inter function delay millisecond 3 Read the Validate barcode on the same page...

Page 73: ...for data collection the onscreen keypad of iPhone iPad will disappear by default Have the scanner read the Show or Hide Keypad barcode to show or hide the keypad if necessary Show or Hide Keypad Read...

Page 74: ...connection By default this function is set to Disable Disable Enable Note Simple pairing only supports to the device with Bluetooth v2 1 or later 2 1 11 BT HID SLAVE MASTER SWITCHING By default the BT...

Page 75: ...ransmission speed will be Inter Function Delay 0 254 1 Read the barcode above to specify the inter function delay 2 Read the Decimal Value barcode on page 263 for the desired inter function delay mill...

Page 76: ...Beep Enable Error Beep Disable Error Beep Note We suggest enabling the error beep so that you will be notified of such data loss and have the scanner re read data 2 2 4 BT SPP SLAVE HARDWARE FLOW CONT...

Page 77: ...though it is idle during the specified time interval for Auto Power Off It will automatically turn off when the time is up Refer to 1 1 3 Power Economy vs WPAN Connection 2 3 1 ACTIVATE BT SPP MASTER...

Page 78: ...etter upper lower case SeTcOn and the barcode must be the Code 128 symbology Usage 1 Read the Activate Bluetooth SPP Master Mode barcode above and barcodes for connection settings such as authenticati...

Page 79: ...2 INTER FUNCTION DELAY By default the inter function delay is set to zero Specify a value ranging from 0 to 254 in units of millisecond to match the computer response time of the keyboard interface Su...

Page 80: ...notification data loss will occur ACK NAK Time out after 0 99 1 Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host 2 Read the Decima...

Page 81: ...HARDWARE FLOW CONTROL By default the data sending via Bluetooth SPP doesn t employ hardware flow control In some cases users may want to enable hardware flow control to prevent data loss during trans...

Page 82: ...it is manually entered via the keyboard For example run a text editor on your computer to receive the data Keyboard Wedge Settings Defaults Keyboard Type PCAT US Alphabets Layout Normal Digits Layout...

Page 83: ...type is set to PCAT US The following keyboard types are supported when using the cradle with the keyboard wedge cable provided No Keyboard Type No Keyboard Type 1 PCAT US 18 PS55 001 3 2 PCAT French...

Page 84: ...y default the alphabets layout is set to normal mode also known as the standard English layout Select French or German keyboard layout if necessary The scanner will make adjustments when sending the A...

Page 85: ...special characters French Keyboard Style AZERTY French layout see below for French Keyboard Style Select Upper Row for the Digits Layout setting for the lower row is for special characters German Keyb...

Page 86: ...n keyboard types languages is unavailable but required Capital Lock Type Setting In order to send the alphabets with correct case the scanner needs to know the status of Caps Lock on the keyboard Inco...

Page 87: ...the status of Caps Lock on the keyboard is ON transmitted characters are exactly the same as in the barcode when case sensitive is selected for Alphabets Transmission Refer to the Capital Lock Type a...

Page 88: ...ing that the alphabets will be transmitted according to their original case the status of Caps Lock on the keyboard as well as the Capital Lock setting Select Ignore Case to have alphabets transmitted...

Page 89: ...ion Kanji Transmission is supported by the scanner when either Bluetooth HID Keyboard Wedge via cradle or USB HID via cradle is selected for the output interface By Kanji Transmission when the host co...

Page 90: ...ng inter connected Enable Disable 2 4 3 INTER CHARACTER DELAY By default the inter character delay is set to zero Specify a value ranging from 0 to 254 in units of millisecond to match the computer re...

Page 91: ...y 0 254 1 Read the barcode above to specify the inter function delay 2 Read the Decimal Value barcode on page 263 for the desired inter function delay millisecond 3 Read the Validate barcode on the sa...

Page 92: ...You may run HyperTerminal exe on your computer and the scanned data will be transmitted to the computer RS 232 Settings Defaults Baud Rate Data Bit Parity Stop Bit 115200 bps 8 bits No parity 1 stop b...

Page 93: ...2564MR Barcode Scanner User Guide 4800 bps 2400 bps 1200 bps 600 bps 2 5 3 DATA BITS 8 bits 7 bits 2 5 4 PARITY No parity Even Odd 82 Enter Setup...

Page 94: ...d the scanner will then wait for the CTS signal to become active Data will not be sent until the CTS signal becomes active Data Ready The RTS signal will be activated after each good read The scanner...

Page 95: ...1 0x1F being transmitted The longer the delay time is the slower the transmission speed will be Inter Function Delay 0 254 1 Read this barcode above to specify the inter function delay 2 Read the Deci...

Page 96: ...Validate barcode on the same page to complete this setting ACK NAK Error Beep Enable Error Beep Disable Error Beep Note We suggest enabling the error beep so that you will be notified of such data lo...

Page 97: ...to the computer Warning When the cradle is solely on USB power the provided current may be insufficient for it to function normally You must connect the power supply cord HID Settings Defaults Keyboa...

Page 98: ...Refer to the table below for the number of desired keyboard type 3 Read the Validate barcode on the same page to complete this setting USB HID By default the keyboard type is set to PCAT US The follo...

Page 99: ...s layout is set to normal mode also known as the standard English layout Select French or German keyboard layout if necessary The scanner will make adjustments when sending the A Q W Z Y and M charact...

Page 100: ...for special characters French Keyboard Style AZERTY French layout see below for French Keyboard Style Select Upper Row for the Digits Layout setting for the lower row is for special characters German...

Page 101: ...r AZERTY keyboard Normal Upper Row Lower Row Note This setting is to be used with the Character Substitution setting when support to certain keyboard types languages is unavailable but required Capita...

Page 102: ...Assuming that the status of Caps Lock on the keyboard is ON transmitted characters are exactly the same as in the barcode when case sensitive is selected for Alphabets Transmission Refer to the Capit...

Page 103: ...keyboard only Ignore Case Case sensitive Digits Transmission By default the alphanumeric keypad is used for transmitting digits Select Numeric Keypad if you wish to use the keys on the numeric keypad...

Page 104: ...he scanner is able to transmit Japanese characters including the Chinese characters used in modern Japanese writing system Kanji Transmission is disabled by default Enable disable scanner s Kanji Tran...

Page 105: ...et to zero Specify a value ranging from 0 to 254 in units of millisecond to match the computer response time of the keyboard interface Such delay time is inserted between every function code 0x01 0x1F...

Page 106: ...01 0x1F defined in the Keyboard Wedge Table However users may want to get rid of these special codes within the barcodes to avoid data error You can decide whether to apply the special keyboard featur...

Page 107: ...later is required Please remove older versions 2 7 1 ACTIVATE USB VIRTUAL COM Activate Cradle USB Virtual COM 2 7 2 INTER FUNCTION DELAY By default the inter function delay is set to zero Specify a v...

Page 108: ...notification data loss will occur ACK NAK Time out after 0 99 1 Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host 2 Read the Decima...

Page 109: ...DLE AUTO RECONNECTION Users can decide whether to have the scanner automatically reconnect to a paired device after disconnection and the occasion for reconnecting Auto reconnect immediately Auto reco...

Page 110: ...ction and Serial No labels Interface Option Reference Keyboard Wedge 2 4 Keyboard Wedge via BT Cradle RS 232 2 5 RS 232 via BT Cradle USB HID 2 6 USB HID via BT Cradle USB Virtual COM 2 7 USB Virtual...

Page 111: ...is flashing blue On Off ratio 0 5 s 0 5 s Once connected the scanner will respond with three beeps tone ascending from low to high and the LED flashes blue On Off ratio 0 02 s 3 s When out of range t...

Page 112: ...river first 3 The scanners will connect to your computer via the cradle 4 Have one scanner read the Enter Setup barcode to enter the configuration mode 5 Have the scanner read the desired interface ba...

Page 113: ...Activate BT HID Select Keyboard Type Activate BT SPP Slave Mode Activate BT SPP Master Mode 3 Have the scanner read the barcodes related to WPAN settings such as Device Name Broadcasting Authenticatio...

Page 114: ...wever broadcasting must be enabled for establishing an initial connection with the scanner For example you can disable device name broadcasting after successfully connecting the scanner to WorkStation...

Page 115: ...ner User Guide 1 Read the barcode above to configure the device name 2 Read the Hexadecimal Value barcode on page 264 for the desired character string 3 Read the Validate barcode to complete this sett...

Page 116: ...tempt will be turned down by the scanner See step 8 in 3 2 3 Connect to Dongle 1 Read the Use preset PIN barcode to enable authentication with a preset PIN Use Preset PIN 2 Read one of the barcodes to...

Page 117: ...e scanner read the setup barcode Enter PIN Code in Decimal or Enter PIN Code in Hexadecimal to input the matching PIN code Refer to Disable Authentication or Use Random PIN Secure Simple Pairing SSP S...

Page 118: ...edure By default BT HID is activated on the scanner and the keyboard type is set to PCAT US When BT HID is re activated you will have to select a keyboard type to complete this setting The procedure i...

Page 119: ...e check the Serial Number label on the scanner to ensure connecting with the correct scanner Select the target scanner If the target scanner does not appear on the list click Search Again to refresh t...

Page 120: ...Chapter 3 Setting up a WPAN Connection 7 Click Next 8 Enter the passkey for authentication which must be exactly the same as configured for the scanner 109 Update...

Page 121: ...2564MR Barcode Scanner User Guide 9 Click Next Wait for a few seconds for Windows to exchange passkeys 110 Enter Setup...

Page 122: ...tting up a WPAN Connection Note When Bluetooth security is enabled without providing a pre set PIN code dynamic input of PIN code is supported 10 Click Finish 2564 as BT SPP Slave 2564 as BT SPP Maste...

Page 123: ...ired application on your computer such as HyperTerminal exe if using BT SPP or Notepad exe if using BT HID The status of the scanner listed on the device list will be updated to Connected indicating t...

Page 124: ...Chapter 3 Setting up a WPAN Connection BT SPP Connected BT SPP Disconnected 113 Update...

Page 125: ...7 Code 39 125 4 8 Trioptic Code 39 129 4 9 Code 93 130 4 10 Code 128 132 4 11 GS1 128 EAN 128 132 4 12 ISBT 128 135 4 13 GS1 DataBar RSS Family 137 4 14 MSI 142 4 15 EAN 8 145 4 16 EAN 13 146 4 17 UC...

Page 126: ...e CLSI editing strips the start stop characters and inserts a space after the first fifth and tenth characters of a 14 character Codabar barcode Apply CLSI Editing Do Not Apply Note The 14 character b...

Page 127: ...e the check digit s the barcode contains 1 Read the barcode to enable either Max Min Length qualification or Fixed Length s qualification Enable Max Min Length 1 55 Enable Fixed Length s 2 Read the ba...

Page 128: ...2564MR Barcode Scanner User Guide 4 2 CODE 25 INDUSTRIAL 25 Enable Disable 118 Enter Setup...

Page 129: ...gth is selected up to 2 fixed lengths can be specified Note The specified length s must include the check digit s the barcode contains 1 Read the barcode to enable either Max Min Length qualification...

Page 130: ...e check digit When desired select one of the algorithms USS or OPCC If incorrect the barcode will not be accepted Do Not Verify USS Check Digit OPCC Check Digit 4 3 2 TRANSMIT CHECK DIGIT Decide wheth...

Page 131: ...O EAN 13 Decide whether to convert a 14 character barcode into EAN 13 if the following requirements are met The barcode must have a leading 0 and a valid EAN 13 check digit Verify Check Digit must be...

Page 132: ...is selected up to 2 fixed lengths can be specified Note The specified length s must include the check digit s the barcode contains 1 Read the barcode to enable either Max Min Length qualification or F...

Page 133: ...Verify Matrix 25 Check Digit Do Not Verify 4 4 2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted Transmit Matrix 25 Check Digit Do Not Transmit 4 4 3 CODE...

Page 134: ...barcode contains 1 Read the barcode to enable either Max Min Length qualification or Fixed Length s qualification Enable Max Min Length 1 55 Enable Fixed Length s 2 Read the barcode for Max Length or...

Page 135: ...Chapter 4 Changing Symbology Settings 4 6 ITALIAN PHARMACODE CODE 32 Enable Disable Note Code 39 must be enabled first 4 7 CODE 39 Enable 125 Update...

Page 136: ...ccepted Verify Code 39 Check Digit Do Not Verify 4 7 2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted Transmit Code 39 Check Digit Do Not Transmit 4 7 3 S...

Page 137: ...arcode is read by qualifying the allowable code length If Max Min Length is selected the maximum length and the minimum length must be specified It only accepts those barcodes with lengths that fall b...

Page 138: ...ength or Fixed Length 1 and follow steps 3 4 Repeat steps 2 4 for Min Length or Fixed Length 2 Max Length 55 or Fixed Length 1 Min Length 4 or Fixed Length 2 3 Read the Decimal Value barcode on page 2...

Page 139: ...e whether to decode Trioptic Code 39 Trioptic Code 39 is a variant of Code 39 used in the marking of computer tap cartridges It always contains six characters Enable Disable Note Trioptic Code 39 and...

Page 140: ...2564MR Barcode Scanner User Guide 4 9 CODE 93 Enable Disable 130 Enter Setup...

Page 141: ...gth is selected up to 2 fixed lengths can be specified Note The specified length s must include the check digit s the barcode contains 1 Read the barcode to enable either Max Min Length qualification...

Page 142: ...2564MR Barcode Scanner User Guide 4 10 CODE 128 Enable Disable 4 11 GS1 128 EAN 128 132 Enter Setup...

Page 143: ...whether to apply a field separator to convert the FNC1 control character to human readable character Enable Field Separator 1 Read the barcode above to enable field separator 2 Read the Hexadecimal V...

Page 144: ...ble GS1 Formatting You may want to add an application ID mark 1 character long to the left AIMark1 or right AIMark2 of an application ID AI for the purpose of labeling it when formatting the GS1 data...

Page 145: ...ISBT Concatenation There must be two ISBT barcodes in order for the scanner to decode and perform concatenation It does not decode single ISBT barcodes Auto discriminate ISBT Concatenation It decodes...

Page 146: ...2 20 times when ISBT concatenation is enabled ISBT Concatenation Redundancy 2 20 10 1 Read the barcode above to specify the concatenation redundancy 2 Read the Decimal Value barcode on page 263 for t...

Page 147: ...Bar Stacked GS1 DataBar Stacked Omnidirectional Group II GS1 DataBar Expanded RSS Expanded This group consists of the following GS1 DataBar Expanded GS1 DataBar Expanded Stacked Group III GS1 DataBar...

Page 148: ...ataBar Stacked Omnidirectional Transmit Code ID Decide whether to include the Code ID in the data being transmitted Transmit RSS 14 Code ID Do Not Transmit Transmit Application ID Decide whether to in...

Page 149: ...GS1 DataBar Expanded GS1 DataBar Expanded Stacked Transmit Code ID Decide whether to include the Code ID in the data being transmitted Transmit RSS Expanded Code ID Do Not Transmit GS1 Formatting for...

Page 150: ...itted Transmit RSS Limited Code ID Do Not Transmit Transmit Application ID Decide whether to include the Application ID 01 in the data being transmitted Transmit RSS Limited Application ID Do Not Tran...

Page 151: ...ecide whether to apply a field separator to convert the GS control character to human readable character The field separator is automatically added to the data when GS1 formatting is enabled Specify F...

Page 152: ...want to remove the AI mark 3 Read the Validate barcode to complete this setting 4 14 MSI Enable Disable 4 14 1 VERIFY CHECK DIGIT Select one of the three calculations to verify check digit s when dec...

Page 153: ...h If Max Min Length is selected the maximum length and the minimum length must be specified It only accepts those barcodes with lengths that fall between max min lengths specified If Fixed Length is s...

Page 154: ...er Guide Max Length 55 or Fixed Length 1 Min Length 4 or Fixed Length 2 3 Read the Decimal Value barcode on page 263 for the desired length 4 Read the Validate barcode on the same page to complete thi...

Page 155: ...EAN 8 No Addon Disable EAN 8 Addon 2 Enable EAN 8 Addon 2 Disable EAN 8 Addon 5 Enable EAN 8 Addon 5 Disable 4 15 1 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being tra...

Page 156: ...No Addon Disable Decide whether to read EAN 13 barcodes ending with Addon 2 EAN 13 Addon 2 Enable EAN 13 Addon 2 Disable Decide whether to read EAN 13 barcodes ending with Addon 5 EAN 13 Addon 5 Enabl...

Page 157: ...tarting with 378 379 won t be decoded if the scanned barcodes do not have the Addon 2 or Addon 5 suffix EAN 13 378 379 Addon Mode Enable Disable Decide whether to enable EAN 13 977 Addon Mode When ena...

Page 158: ...e Enable Disable Decide whether to enable EAN 13 491 Addon Mode When enabled barcodes starting with 491 won t be decoded if the scanned barcodes do not have the Addon 2 or Addon 5 suffix EAN 13 491 Ad...

Page 159: ...ending from high to low when decoding the scanned barcode that doesn t have the Addon 2 or Addon 5 suffix EAN 13 Addon Mode Buzzer Enable Disable 4 16 2 CONVERT TO ISBN Decide whether to convert the E...

Page 160: ...convert the EAN 13 barcode starting with 977 to ISSN Convert EAN 13 to ISSN Do Not Convert 4 16 4 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted Transmit...

Page 161: ...de whether to decode the following barcodes as Coupon Code UPC A barcodes starting with digit 5 EAN 13 barcodes starting with digits 99 UPC A EAN 128 Coupon Codes Enable Disable Note Depending on your...

Page 162: ...UPC A Enable UPC A No Addon Disable UPC A Addon 2 Enable UPC A Addon 2 Disable UPC A Addon 5 Enable UPC A Addon 5 Disable 4 18 1 CONVERT TO EAN 13 Decide whether to expand the read UPC A barcode as we...

Page 163: ...ert UPC A to EAN 13 Do Not Convert 4 18 2 TRANSMIT SYSTEM NUMBER Decide whether to include the system number in the data being transmitted Transmit UPC A System Number Do Not Transmit 4 18 3 TRANSMIT...

Page 164: ...2 Disable UPC E Addon 5 Enable UPC E Addon 5 Disable 4 19 1 SELECT SYSTEM NUMBER Decide whether to decode the ordinary UPC E barcodes only or both UPC E0 and UPC E1 barcodes System number 0 enabled f...

Page 165: ...into UPC E1 barcodes 4 19 2 CONVERT TO UPC A Decide whether to expand the read UPC E barcode as well as its addons into UPC A After conversion the data follows UPC A format and is affected by UPC A pr...

Page 166: ...e check digit in the data being transmitted Transmit UPC E Check Digit Do Not Transmit 4 20 CODE 11 Enable Disable 4 20 1 VERIFY CHECK DIGIT Decide whether to verify the check digit s If incorrect the...

Page 167: ...length If Max Min Length is selected the maximum length and the minimum length must be specified It only accepts those barcodes with lengths that fall between max min lengths specified If Fixed Lengt...

Page 168: ...er Guide Max Length 55 or Fixed Length 1 Min Length 4 or Fixed Length 2 3 Read the Decimal Value barcode on page 263 for the desired length 4 Read the Validate barcode on the same page to complete thi...

Page 169: ...and application ID mark will be automatically added to the output data Enable GS1 Formatting Disable GS1 Formatting 4 21 2 COMPOSITE CC C Decide whether to enable Composite CC C Enable Composite CC C...

Page 170: ...d Transmit UPC barcodes regardless of whether a 2D barcode is detected UPC Always Linked Transmit UPC barcodes and the 2D portion If the 2D portion is not detected the UPC barcode will not be transmit...

Page 171: ...ng is enabled Specify Field Separator 1 Read the barcode above to specify field separator 2 Read the Hexadecimal Value barcode on page 264 for the desired character string 3 Read the Validate barcode...

Page 172: ...code Scanner User Guide 2 Read the Hexadecimal System barcode on page 264 for the desired character Read 00 if you want to remove the AI mark 3 Read the Validate barcode to complete this setting 162 E...

Page 173: ...2 1 US POSTNET Enable US Postnet Disable 4 22 2 US PLANET Enable US Planet Disable 4 22 3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted Transmit US Posta...

Page 174: ...Enable UK Postal Disable 4 23 2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted Transmit UK Postal Check Digit Do Not Transmit 4 24 MORE POSTAL CODE 4 24...

Page 175: ...2 AUSTRALIAN POSTAL Enable Australian Postal Disable 4 24 3 DUTCH POSTAL Enable Dutch Postal Disable 4 24 4 USPS 4CB ONE CODE INTELLIGENT MAIL Enable USPS 4CB One Code Intelligent Mail Disable 4 24 5...

Page 176: ...2564MR Barcode Scanner User Guide Disable 4 25 2D SYMBOLOGIES 4 25 1 PDF417 Enable PDF417 Disable 4 25 2 MicroPDF417 166 Enter Setup...

Page 177: ...7 Disable 4 25 3 DATA MATRIX Enable Data Matrix Disable GS1 FORMATTING Decide whether to enable GS1 formatting for GS1 Data Matrix barcodes When enabled the field separator and application ID mark wil...

Page 178: ...for the desired character string 3 Read the Validate barcode to complete this setting APPLICATION ID MARK You may want to add an application ID mark 1 character long to the left AIMark1 or right AIMar...

Page 179: ...ether to decode mirror image Data Matrix barcodes Never do not decode Data Matrix barcodes that are mirror images Always decode only Data matrix barcodes that are mirror images Auto decode both mirror...

Page 180: ...to the output data Enable Disable FIELD SEPARATOR GS CHARACTER Decide whether to apply a field separator to convert the GS control character to human readable character The field separator is automati...

Page 181: ...eling it when formatting the GS1 data AIMark1 AIMark2 1 Read the barcode above to add a mark to the left AIMark1 right AIMark2 of an application ID 2 Read the Hexadecimal Value barcode on page 264 for...

Page 182: ...ding Buffer All Symbols Transmit Macro PDF When Complete Transmit all decoded data from an entire Macro PDF sequence only when the entire sequence is scanned and decoded If the decoded data exceeds th...

Page 183: ...if enabled is always sent with GLI formatting GLI Protocol None 4 26 3 TRANSMIT CONTROL HEADER The control header contains the segment index and file ID For example the field may be 92800000 725 120 3...

Page 184: ...Code and Suffix Code before transmission Prefix Code Processed Data Suffix Code IN THIS CHAPTER 5 1 Letter Case 175 5 2 Character Substitution 176 5 3 Prefix Suffix Code 188 5 4 Code ID 189 5 5 Length...

Page 185: ...l then become applicable You may decide whether or not to apply Key Status when Normal Key is selected for Key Type Key Type Key Status Scan Code Only 1 scan code value is allowed Refer to 5 2 1 Selec...

Page 186: ...acter substitution For example KEY TYPE NORMAL Read 3 0 2 and D to replace the character 0 with a dash Read 3 0 2 D 3 and 0 to replace the character 0 with a dash 0 KEY TYPE SCAN CODE If you want to r...

Page 187: ...s not desired with one or more symbologies read the Do Not Apply barcode for each undesired symbologies and all the three sets will be ignored for them Character Substitution for Codabar Apply Do Not...

Page 188: ...128 Apply Do Not Apply Character Substitution for GS1 128 Apply Do Not Apply Character Substitution for ISBT 128 Apply Do Not Apply Character Substitution for EAN 8 No Addon Apply Do Not Apply Charac...

Page 189: ...y Do Not Apply Character Substitution for EAN 13 No Addon Apply Do Not Apply Character Substitution for EAN 13 Addon 2 Apply Do Not Apply Character Substitution for EAN 13 Addon 5 Apply Do Not Apply C...

Page 190: ...strial 25 Apply Do Not Apply Character Substitution for Interleaved 25 Apply Do Not Apply Character Substitution for Matrix 25 Apply Do Not Apply Character Substitution for Chinese 25 Apply Do Not App...

Page 191: ...ply Do Not Apply Character Substitution for UPC A No Addon Apply Do Not Apply Character Substitution for UPC A Addon 2 Apply Do Not Apply Character Substitution for UPC A Addon 5 Apply Do Not Apply Ch...

Page 192: ...ply Do Not Apply Character Substitution for UPC E Addon 5 Apply Do Not Apply Character Substitution for UCC Coupon Extended Code Apply Do Not Apply Character Substitution for Code 11 Apply Do Not Appl...

Page 193: ...CC C Apply Do Not Apply Character Substitution for Composite TLC 39 Apply Do Not Apply Character Substitution for US Postnet Apply Do Not Apply Character Substitution for US Planet Apply Do Not Apply...

Page 194: ...t Apply Character Substitution for Australian Postal Apply Do Not Apply Character Substitution for Dutch Postal Apply Do Not Apply Character Substitution for USPS 4CB One Code Intelligent Mail Apply D...

Page 195: ...417 Apply Do Not Apply Character Substitution for MicroPDF417 Apply Do Not Apply Character Substitution for Data Matrix Apply Do Not Apply Character Substitution for Maxicode Apply Do Not Apply Charac...

Page 196: ...Chapter 5 Defining Output Format Character Substitution for MicroQR Apply Do Not Apply Character Substitution for Aztec Apply Do Not Apply 187 Update...

Page 197: ...to apply Key Status when Normal Key is selected for Key Type Key Type Key Status Scan Code Up to 4 scan code values are allowed N A Normal Key Up to 8 character strings are allowed Add Shift Add Left...

Page 198: ...me applicable You may decide whether or not to apply Key Status when Normal Key is selected for Key Type Key Type Key Status Scan Code Only 1 scan code value is allowed N A Normal Key Up to 2 characte...

Page 199: ...E S E C E E EAN 8 P B B FF E EAN 13 M A A F E UPC A J A A A E MSI V V D P M UCC Coupon Code G F I C C Code 11 K J J D H Composite CC A B L X M J La Composite CC C N Y N O Lc Composite TLC 39 O Z O R L...

Page 200: ...Chapter 5 Defining Output Format MicroQR f T R Y Q Aztec g U Q Z z IATA z z r h S Macro PDF417 p i a q L Macro MicroPDF417 q j b r L 191 Update...

Page 201: ...applying the character D for Code ID 3 Read the Validate barcode to complete this setting Configure Code ID for Codabar Configure Code ID for Code 39 Configure Code ID for Trioptic Code 39 Configure...

Page 202: ...r Chinese 25 Configure Code ID for MSI Configure Code ID for UPC A Configure Code ID for UPC E Configure Code ID for UCC Coupon Code Configure Code ID for Code 11 Configure Code ID for Composite CC A...

Page 203: ...gure Code ID for Australian Postal Configure Code ID for Dutch Postal Configure Code ID for USPS 4CB One Code Intelligent Mail Configure Code ID for UPU FICS Postal Configure Code ID for PDF417 Config...

Page 204: ...at Configure Code ID for MicroQR Configure Code ID for Aztec Configure Code ID for IATA Configure Code ID for Macro PDF417 Configure Code ID for Macro MicroPDF417 5 4 3 CLEAR CODE ID SETTINGS Clear Al...

Page 205: ...d in front of data being transmitted Such Length code can be individually enabled or disabled for each symbology Length Code for Codabar Apply Do Not Apply Length Code for Code 39 Apply Do Not Apply L...

Page 206: ...o Not Apply Length Code for GS1 128 GS1 DataBar Apply Do Not Apply Length Code for ISBT 128 Apply Do Not Apply Length Code for EAN 8 Apply Do Not Apply Length Code for EAN 13 Apply Do Not Apply Length...

Page 207: ...Do Not Apply Length Code for Industrial 25 Apply Do Not Apply Length Code for Interleaved 25 Apply Do Not Apply Length Code for Matrix 25 Apply Do Not Apply Length Code for Chinese 25 Apply Do Not Ap...

Page 208: ...o Not Apply Length Code for UPC A Apply Do Not Apply Length Code for UPC E Apply Do Not Apply Length Code for UCC Coupon Extended Code Apply Do Not Apply Length Code for Code 11 Apply Do Not Apply Len...

Page 209: ...ot Apply Length Code for Composite CC C Apply Do Not Apply Length Code for Composite TLC 39 Apply Do Not Apply Length Code for US Postnet Apply Do Not Apply Length Code for US Planet Apply Do Not Appl...

Page 210: ...h Code for Japan Postal Apply Do Not Apply Length Code for Australian Postal Apply Do Not Apply Length Code for Dutch Postal Apply Do Not Apply Length Code for USPS 4CB One Code Intelligent Mail Apply...

Page 211: ...ply Do Not Apply Length Code for PDF417 Apply Do Not Apply Length Code for MicroPDF417 Apply Do Not Apply Length Code for Data Matrix Apply Do Not Apply Length Code for Maxicode Apply Do Not Apply Len...

Page 212: ...Chapter 5 Defining Output Format Apply Do Not Apply Length Code for MicroQR Apply Do Not Apply Length Code for Aztec Apply Do Not Apply 5 6 MULTI BARCODE EDITOR 203 Update...

Page 213: ...arcodes the maximum output data length of all the barcodes is 10 KB after configuration When the data length exceeds 10 KB the concatenation will not take effect Note The Multi Barcode Editor has noth...

Page 214: ...leaved 25 65 e Trioptic Code 39 46 F Matrix 25 47 G Codabar NW7 67 g Code 11 48 H Code 93 49 I Code 128 4A J UPC E0 UPC E1 6A j Composite CC C 4B K UPC E with Addon 2 6B k PDF417 4C L UPC E with Addon...

Page 215: ...ting of the barcode set 5 6 2 ACTIVATE THE CONCATENATION OF BARCODES By default the output sequence editing of the concatenation of barcodes is not applied When Enforce Output Sequence is enabled all...

Page 216: ...from the starting position of barcode data until a different character is met For example if it is configured to remove the character 0 hex value is 30 one or more zeros will be stripped off the barc...

Page 217: ...ty code ID in front of the barcode that shares the common purpose of identifying tracking recording storing and communicating essential business personal or product data Enabling this function can hav...

Page 218: ...ration If the data length exceeds 7 KB editing format will not take effect Prefix Code Code ID Length Code Data Suffix Code Additional Field s None by default None by default None by default Barcode i...

Page 219: ...irectly apply the editing format If not you must start with configuring an editing format first and then activate the editing format when it is desired in use Editing Format 1 Enable Disable Editing F...

Page 220: ...meeting with the criteria are processed normally When Exclusive Data Editing is enabled all barcodes read by the scanner must be processed by the editing formats If data is found excluded from all ena...

Page 221: ...mat Format 1 5 and the parameters pertaining to the editing format can then be configured applicable code type data length matching string location start position field adjustment total number of fiel...

Page 222: ...g of an editing format if you have the scanner read any barcode for parameters other than those pertaining to the editing format it will automatically abort the programming process End Programming For...

Page 223: ...listed below Editing format Defaults Applicable Code Type All Data Length 0 No qualification Matching String Disable Matching String Location None Start Position From head Field Adjustment No adjustm...

Page 224: ...ing format Note Data editing cannot be performed unless the three conditions are all met 6 3 1 APPLICABLE CODE TYPE By default barcodes of all the supported symbologies will be processed by any editin...

Page 225: ...or Codabar Apply Do Not Apply Editing Format for Code 39 Apply Do Not Apply Editing Format for Trioptic Code 39 Apply Do Not Apply Editing Format for Code 93 Apply Do Not Apply Editing Format for Code...

Page 226: ...rmat for GS1 128 GS1 DataBar Apply Do Not Apply Editing Format for ISBT 128 Apply Do Not Apply Editing Format for EAN 8 Apply Do Not Apply Editing Format for EAN 8 Addon 2 Apply Do Not Apply Editing F...

Page 227: ...Apply Do Not Apply Editing Format for EAN 13 Addon 2 Apply Do Not Apply Editing Format for EAN 13 Addon 5 Apply Do Not Apply Editing Format for Italian Pharmacode Apply Do Not Apply Editing Format for...

Page 228: ...diting Format for Interleaved 25 Apply Do Not Apply Editing Format for Matrix 25 Apply Do Not Apply Editing Format for Chinese 25 Apply Do Not Apply Editing Format for MSI Apply Do Not Apply Editing F...

Page 229: ...A Addon 2 Apply Do Not Apply Editing Format for UPC A Addon 5 Apply Do Not Apply Editing Format for UPC E Apply Do Not Apply Editing Format for UPC E Addon 2 Apply Do Not Apply Editing Format for UPC...

Page 230: ...UCC Coupon Extended Code Apply Do Not Apply Editing Format for Code 11 Apply Do Not Apply Editing Format for Composite CC A B Apply Do Not Apply Editing Format for Composite CC C Apply Do Not Apply Ed...

Page 231: ...Postnet Apply Do Not Apply Editing Format for US Planet Apply Do Not Apply Editing Format for UK Postal Apply Do Not Apply Editing Format for Japan Postal Apply Do Not Apply Editing Format for Austral...

Page 232: ...utch Postal Apply Do Not Apply Editing Format for USPS 4CB One Code Intelligent Mail Apply Do Not Apply Editing Format for UPU FICS Postal Apply Do Not Apply Editing Format for PDF417 Apply Do Not App...

Page 233: ...t for Data Matrix Apply Do Not Apply Editing Format for Maxicode Apply Do Not Apply Editing Format for QR Code Apply Do Not Apply Editing Format for MicroQR Apply Do Not Apply Editing Format for Aztec...

Page 234: ...n Length 2 Read the Decimal Value barcode on page 263 for the desired length 3 Read the Validate barcode on the same page to complete this setting 6 3 3 MATCHING STRING LOCATION By default no matching...

Page 235: ...cation of the matching string Location of Matching String 5 Read the Decimal Value barcode on page 263 for the desired location 6 Read the Validate barcode on the same page to complete this setting 6...

Page 236: ...he desired field length 3 Read the Validate barcode on the same page to complete this setting 6 4 3 TOTAL NUMBER OF FIELDS Data can be divided into at most 6 fields each of them is numbered from F1 to...

Page 237: ...The scanner will search for the occurrence of this particular string in the data By default this string will be included in the field You may discard it By Length Alternatively you may simply specify...

Page 238: ...Setting 1 Read the barcode below to divide field 2 by a specified terminating string Select Field Separator to Divide Field 2 2 Read the Hexadecimal Value barcode on page 264 for the desired character...

Page 239: ...Separator to Divide Field 3 2 Read the Hexadecimal Value barcode on page 264 for the desired character string 3 Read the Validate barcode to complete this setting 4 Read the Discard Separator barcode...

Page 240: ...Select Field Separator to Divide Field 4 2 Read the Hexadecimal Value barcode on page 264 for the desired character string 3 Read the Validate barcode to complete this setting 4 Read the Discard Sepa...

Page 241: ...Separator to Divide Field 5 2 Read the Hexadecimal Value barcode on page 264 for the desired character string 3 Read the Validate barcode to complete this setting 4 Read the Discard Separator barcode...

Page 242: ...is configured for interface Key Type and Key Status will then become applicable You may decide whether or not to apply Key Status when Normal Key is selected for Key Type Key Type Key Status Scan Code...

Page 243: ...2564MR Barcode Scanner User Guide 2 Read the Hexadecimal Value barcode on page 264 for the desired additional field 3 Read the Validate barcode to complete this setting 234 End Programming Format...

Page 244: ...ield Time 1 16 sec 1 1 Read the barcode above to specify the time interval for the Pause Field It is set to 1 by default 2 Read the Decimal Value barcode on page 263 For example read 1 and 0 for setti...

Page 245: ...ny desired order and fields can be assigned multiple times as well Note Up to twelve fields can be assigned 1 Read the Start barcode to begin with programming the field transmission sequence Start Pro...

Page 246: ...Chapter 6 Applying Formats for Data Editing Additional Field 4 Additional Field 5 Pause Field Null Character Field 3 Read the End barcode to complete this setting End Programming 237 Update...

Page 247: ...ength to 9 Field 1 data starts from the 1st character to the 9th character 6 Read the Divide Field 2 by Length barcode and set length to 10 Field 2 data starts from the 10th character to the 19th char...

Page 248: ...the Three Fields barcode 4 Read the Divide Field 1 by Length barcode and set length to 6 Field 1 data starts from the 1st character to the 6th character 5 Read the Select Field Separator to Divide Fi...

Page 249: ...overage line of sight 100 meters with the cradle Interface Supported Serial Port Profile BT SPP Human Interface Device Profile BT HID Cradle Physical Characteristics Memory 10 KB for transmit buffer 4...

Page 250: ...drops per 6 sides Splash Dust Resistance IP 54 Electrostatic Discharge 20 kV air discharge 10 kV contact discharge Programming Support Configuration Setup barcodes or host serial commands Software Wi...

Page 251: ...For USB Virtual COM you may need to install its driver first 2 Connect the power supply cord from the cradle to a proper power outlet 3 Refer to 3 1 1 Connect to Cradle for the target scanner to conne...

Page 252: ...User Program K2564_V shx STD2564_V shx For the communication settings select RS 232 and the correct COM port for RS 232 or USB Virtual COM interface For RS 232 select 115200 bps for baud rate for USB...

Page 253: ...irtual COM For RS 232 the baud rate setting is still 115200 bps USING BLUETOOTH DONGLE 1 Refer to 3 2 3 Connect to Dongle for the target scanner to accept the connection request from your computer 2 R...

Page 254: ...on your computer Kernel Program User Program K2564_V shx STD2564_V shx For the communication settings select RS 232 and the correct COM port for BT SPP interface Ignore the baud rate setting For the...

Page 255: ...om the cradle to a proper power outlet 3 Refer to 3 1 1 Connect to Cradle for the target scanner to connect to the cradle Read the Set Connection label first and then the Serial Number label Both labe...

Page 256: ...er Kernel Program User Program 2560CradleKV shx 2560CradleUV shx For the communication settings select RS 232 and the correct COM port for RS 232 or USB Virtual COM interface For RS 232 select 115200...

Page 257: ...settings 0x23 0x40 0x31 0x30 0x39 0x39 0x35 0x32 0x0d Note After configuring the scanner you may send the serial command 109999 to save the settings CR Purpose To halt the scanner Remarks 0x23 0x40 0...

Page 258: ...0x45 0x50 0x2c 0x30 0x39 0x0d RLED nn CR Purpose Have the scanner s red LED indicator blink as many times as you specified ranging from 00 to 99 00 is to stop the work The length of blinking time is b...

Page 259: ...beep 101010 CR CR For the scanner to change the beeper frequency to 8 kHz for Good Read Beep only and beep 101001 CR CR For the scanner to change the beeper length to longest for Good Read Beep only a...

Page 260: ...SB Virtual COM you can only configure the first scanner that connects to the cradle To identify the scanner you may send the serial command to have it respond with a beep 2 For BT SPP you can configur...

Page 261: ...bel Both labels can be located at the back of the cradle 4 Refer to 3 1 1 Connect to Cradle for the target scanner to connect to the cradle 5 Read the following barcodes in sequence to configure the c...

Page 262: ...ne scanner connecting to the cradle Here is the setup barcode for this serial command MultiConnection CR Purpose To allow up to seven scanners connecting to the cradle Here is the setup barcode for th...

Page 263: ...ommand GetID CR Purpose To get MAC ID Here is the setup barcode for this serial command Download CR Purpose To download CPU firmware to the cradle via RS 232 or USB Here is the setup barcode for this...

Page 264: ...keyboard 5 times within 3 seconds while the Communication LED on the cradle is flashing red and blue This will change the interface from USB HID to USB Virtual COM and the Communication LED will becom...

Page 265: ...8 0 F2 SP 0 P p 1 INS F3 1 A Q a q 2 DLT F4 2 B R b r 3 Home F5 3 C S c s 4 End F6 4 D T d t 5 Up F7 5 E U e u 6 Down F8 6 F V f v 7 Left F9 7 G W g w 8 BS F10 8 H X h x 9 HT F11 9 I Y i y A LF F12 J...

Page 266: ...c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 BS 8 H X h x 9 HT 9 I Y i y A LF J Z j z B ESC K k C L l D CR M m E N n F O _ o Dly KEY TYPE STATUS KEY TYPE If BT HID USB HID or Keyboard Wedge i...

Page 267: ...I Keyboard Wedge Table Normal Scan Code KEY STATUS Decide whether or not to change key status when Normal Key is selected for Key Type Add Shift Add Left Ctrl Add Right Ctrl Add Left Alt Add Right Alt...

Page 268: ...alidate barcode to complete this setting KEY TYPE NORMAL KEY STATUS SHIFT For example if you want to program the character Shift 1 on keyboard as the prefix code 1 Read the Configure Prefix barcode 2...

Page 269: ...DECIMAL SYSTEM Decimal Validate the Values Appendix IV NUMERAL SYSTEMS 0 1 2 3 4 5 6 7 8 9 Validate 263 Update Abort...

Page 270: ...2564MR Barcode Scanner User Guide HEXADECIMAL SYSTEM Hexadecimal 0 1 2 3 4 5 6 7 8 9 A B C D E F 264 Enter Setup...

Page 271: ...DC1 1 A Q a q 2 STX DC2 2 B R b r 3 ETX DC3 3 C S c s 4 EOT DC4 4 D T d t 5 ENQ NAK 5 E U e u 6 ACK SYN 6 F V f v 7 BEL ETB 7 G W g w 8 BS CAN 8 H X h x 9 HT EM 9 I Y i y A LF SUB J Z j z B VT ESC K...

Page 272: ...allowed Enter PIN in Hexadecimal Enter PIN in Decimal 3 Read the Decimal Value barcode on page 263 or the Hexadecimal Value barcode on page 264 for the desired digits or character string Read the Clea...

Page 273: ...low the steps below to enter the matching PIN on the scanner There is no need to enter the configuration mode 1 Read one of the barcodes to specify the PIN code in decimal or hexadecimal Enter PIN in...

Page 274: ...This appendix provides the setup barcodes required while ScanMaster utility provides GUI setup that is organized and easy to use Note The configured settings are saved in flash memory for access once...

Page 275: ...format some barcodes ex First Name Middle Name Initial Last Name Name suffix Name Prefix Birth Date and so on will return data based on the calculated actual data contained in the ID barcode Full Nam...

Page 276: ...s Postal Code Home Address Line1 Home Address Line2 Home Address City Home Address State Home Address Postal Code License ID Number License Class License Restrictions License Endorsements Height Feet...

Page 277: ...endix V 1 Weight Pounds Weight Kilograms Eye Color Hair Color License Expiration Date Birth Date Gender License Issue Date Issue Timestamp Number of Duplicates Medical Codes Organ Donor 271 Update Abo...

Page 278: ...ser Guide Nonresident Customer ID Social Security Number AKA Birth Date AKA Social Security Name AKA Full Name AKA Last Name AKA First Name AKA Middle Name Initial AKA Name Suffix AKA Name Prefix Weig...

Page 279: ...iscriminator Country Federal Commission Codes Place of Birth Audit Information Inventory Control Race Ethnicity Std Vehicle Class Std Restrictions Std Endorsements Class Description Endorsement Descri...

Page 280: ...estrictions Description Permit Class Permit Expiration Date Permit ID Number Permit Issue Date Permit Restrictions Permit endorsements Issuer ID Number Family Name Truncation First Name Truncation Mid...

Page 281: ...elds with 4 bytes characters Program the transmission sequence by reading the desired fields as additional fields Note Up to 5 separators can be assigned Separator 1 1 byte Space Separator 2 1 byte En...

Page 282: ...dit Separator 2 Edit Separator 3 Edit Separator 4 Edit Separator 5 1 Read the barcode above to apply separator to driver license information separately and follow steps 2 3 2 Read the Hexadecimal Valu...

Page 283: ...Key Type Key Status Scan Code Up to 2 scan code values are allowed N A Normal Key Up to 4 character strings are allowed Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Refer to Keybo...

Reviews: