78
Raption 50 Series Instruction Manual
3- Once clicking over
‘WAN/Cellular’
tab, introduce the ‘APN’ provided by the SIM’s
company. In case of ‘User ID’ and ‘Password’ are required too, it has to be added in
the ‘Advanced’ section.
4- In the
‘Security’
tab, the
‘DMZ Enabled’
must be ‘Disable’, while the
‘Port
Forwarding’
must be ‘Enable’. Then, you will need to add the ports used by the
charger. These ports are next:
Setup Webpage
OCPP Incoming
listening ports *
OCPP Settings
SCP Remote
Access
80
50000
8080
22
Note:
The OCPP Listening port is 50000 by default. If your Central System works with a
different port, add it instead. You will need to configure it afterwards in the OCPP web
settings (http://”IP_ADDRESS”:8080).
See chapter 5.
Make click over
‘Apply’
tab in order to save.