background image

USER'S MANUAL

 

Multimeter 

Auto ranging Pocket DMM

DMR-602

 

 

CIRCUIT-TEST ELECTRONICS

www.circuittest.com

Safety
International Safety Symbols

 

This symbol, adjacent to another symbol or terminal, indicates the user 

must refer to the manual for further information.

 

This symbol, adjacent to a terminal, indicates that, under normal use, 

hazardous voltages may be present.

 

Double insulation

Features

•  3-3/4 digit 4000 count LCD display
•  Built-in non-contact AC voltage detector
•  Flashlight
•  Double Molded housing
•  CATIV 600V
•  200mA/500V Resettable Fused current inputs and 
•  Overload protection on all ranges
•  Autoranging with auto power off

Safety Precautions 

 

This meter has been designed for safe use, but must be operated with caution. The 

rules listed below must be carefully followed for safe operation. 

1.  Do not exceed the maximum rated input limits.

2.   

USE EXTREME CAUTION

 when working with voltages greater than 25VAC 

rms or 35VDC. These voltages are considered a shock hazard.

3.   

DO NOT

 measure voltage if the voltage on the “COM” input jack exceeds 600V 

above earth ground.

4.   

ALWAYS

 discharge capacitors and remove power from the device under test 

before performing Diode, Resistance or Continuity tests.

5.   

NEVER

 connect the meter leads across a voltage source when the function 

switch is in the current, resistance or diode mode. 

6.   

ALWAYS

 turn off the meter and disconnect the test leads from the circuit before 

opening the cover to replace battery.

7.   

ONLY

 operate the meter with the battery cover fastened securely.

Input Limits

Function

Maximum Input

V DC or V AC

600V DC/AC

µA AC/DC

200mA/500V (fast acting resettable fuse)

Resistance, Diode & 

Continuity Test

600V DC/AC

Meter Description

1.   Non-contact AC voltage detector probe tip
2.   Non-contact AC voltage indicator light
3.   3 3/4 Digit (4000 count) 
4.   MODE button
5.   Function switch
6.   Flashlight
7.   Flashlight button
8.   Hz/%Duty Cycle button
9.   Battery Cover
10.   Test leads

Specifications

Function

Range & Resolution

Accuracy

DC Voltage

400mV, 4.000V,40.00V

±(0.8% rdg + 2digits)

400.0V, 600V

±(1.0% rdg + 2digits)

AC Voltage

50-60Hz

4.000V, 40.00V

±(1.0% rdg + 5digits)

400.0V, 600V

±(1.5% rdg + 5digits)

DC Current

400.0µA, 4000µA

±(2.0% rdg + 2digits)

40.00mA, 200.0mA

AC Current

50-60Hz

400.0µA, 4000µA

±(2.5% rdg + 5digits)

40.00mA, 200.0mA

Resistance

400.0Ω

±(0.8% rdg + 5digits)

4.000kΩ, 

±(1.2% rdg + 5digits)

40.00kΩ, 400.0kΩ

±(0.8% rdg + 2digits)

4.000MΩ

±(0.3% rdg + 5digits)

40.00MΩ

±(5.0% rdg + 5digits)

Capacitance

4.000nF

±(5.0% rdg + 0.6nF)

40.00nF

±(3.5% rdg + 30digits)

400.0nF, 4.000µF

±(3.0% rdg + 20digits)

40.00µF, 200.0µF

±(5.0% rdg + 30digits)

Frequency

9.999Hz, 99.999Hz, 999.9Hz, 

9.999kHz, 

±(1.0% rdg + 2digits)

Duty Cycle

0.5-99%

±(2.0% rdg + 5digits)

Non-Contact Voltage 

100 to 600VAC; 50/60Hz

Diode Test    

Test current 1mA, open circuit voltage of 1.5V DC typical

Continuity Check 

Audible signal if the resistance is <100Ω

Display 

  

4000 count 3-3/4 digit LCD

Over range indication 

“OL” is displayed

Polarity    

Automatic; (-)  sign for negative polarity.

Low Battery Indication     

symbol indicates low battery condition.

Input Impedance 

  

>7.5MΩ (VDC & VAC)

AC Response 

Average responding

ACV Bandwidth 

50Hz to 60Hz

Auto Power Off 

15 minutes (approximately)

Fuse 

  

mA, µA ranges; 0.2A/500V fast acting (resettable fuse)

Batteries    

Two 1.5V AAA 

Operating Temperature 

32ºF to 104ºF (0ºC to 40ºC)

Storage Temperature 

14ºF to 122ºF (-10ºC to 50ºC)

Weight  

  

0.319 lb (145g)

Size 

  

104x55x32.5mm (4.09”x2.1”x1.2”)

Safety / Approvals 

This meter is UL and CUL approved and conforms to  

  

IEC61010-1 for Overvoltage Category CAT IV 600V.

Note: 

Accuracy specifications consist of two elements:

• (% reading) This is the accuracy of the measurement circuit 

• (+ digits) This is the accuracy of the analog to digital converter 

Accuracy is stated at 65ºF to 83ºF (18ºC to 28ºC) < 75% RH