- 8 -
Weight
0.753lb (342g) (includes holster).
Size
7.36” x 3.2” x 2.0” (187 x 81 x 50mm) (includes
holster)
Safety / Approvals
This meter is UL and CUL approved and con-
forms to IEC61010-1 for Overvoltage Category
CAT IV 600V and CAT III 1000V
Function
Range
Resolution
Accuracy
DC Voltage
400mV
0.1mV
±(0.5% r 2 digits)
4V
0.001V
±(1.2% r 2 digits)
40V
0.01V
400V
0.1V
1000V
1V
±(1.5% r 10 digits)
AC Voltage
400mV
0.1mV
±(2.0% r 10 digits)
4V
0.001V
±(2.0% r 5 digits)
40V
0.01V
400V
0.1V
1000V
1V
±(2.5% r 5 digits)
DC Current
400uA
0.1uA
±(1.0% r 3 digits)
4000uA
1uA
±(1.5% r 3 digits)
40mA
0.01mA
400mA
0.1mA
10A
0.01A
±(2.5% r 5 digits)
AC Current
400uA
0.1uA
± (2.5% r 10 digits)
4000uA
1uA
±(2.5% r 5 digits)
40mA
0.01mA
400mA
0.1mA
10A
0.01A
±(3.0% r 7 digits)
Note:
Accuracy is stated at 65ºF to 83ºF (18ºC to 28ºC) and less than 75% RH.