- 9 -
Function
Range
Resolution
Accuracy
Resistance
400Ω
0.1Ω
±(1.2% r 4 digits)
4kΩ
0.00k1Ω
±(1.0% r 2 digits)
40kΩ
0.01kΩ
±(1.2% r 2 digits)
400kΩ
0.1kΩ
4MΩ
0.001MΩ
40MΩ
0.01MkΩ
±(2.0% r 3 digits)
Capacitance
4nF
0.001nF
±(5.0% r0.5nF)
40nF
0.01nF
±(5.0% r 7 digits)
400nF
0.1nF
±(3.0% r 5 digits)
4uF
0.001uF
40uF
0.01uF
100uF
0.1uF
±(5.0% r 5 digits)
Frequency
5.999Hz
0.001Hz
±(1.5% r 1 digit)
59.99Hz
0.01Hz
599.9Hz
0.1Hz
±(1.2% r 3 digits)
5.999kHz
0.001kHz
59.99kHz
0.01kHz
599.9kHz
0.1kHz
5.999MHz
0.001MHz
±(1.5% r 4 digits)
9.999mHz
0.001MHz
Sensitivity: 0.5Vrms <500kHz; 3Vrms >500kHz
Duty Cycle
0.1%~99.9%
0.1%
±(1.2% r 2 digits)
Pulse width: 100us to 100ms, Frequency: 5Hz to 150kHz
Temperature
-20°to 750°C
1°C
±(3% r 5°C/9°F)
-4°to 1382 °F
1°F
Note:
Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital converter.