S
ECTION
3: E
MERGENCY
P
ROCEDURES
C
IRRUS
D
ESIGN
S
MOKE
AND
F
IRE
SR20
3-12
P/N 11934-005
Smoke and Fire
Cabin Fire In Flight
1. BAT 1, ALT 1, and ALT 2 Switches.........................OFF, AS REQUIRED
2. Fire Extinguisher ........................................................................ ACTIVATE
3. AVIONICS Switch ...................................................................................OFF
4. All other switches .....................................................................................OFF
5. Land as soon as possible.
◆
If setting master switches off eliminated source of fire or fumes and
airplane is in night, weather, or IFR conditions:
a. Airflow Selector..................................................................................OFF
b. BAT 1, BAT 2, ALT 1, and ALT 2 Switches .................................... ON
c. AVIONICS Switch.............................................................................. ON
d. Required Systems .................................ACTIVATE ONE AT A TIME
e. Temperature Selector ....................................................................COLD
f. Vent Selector............................ FEET/PANEL/DEFROST POSITION
g. Airflow Selector............................... SET AIRFLOW TO MAXIMUM
h. Panel Eyeball Outlets..................................................................... OPEN
i. Land as soon as possible.
Procedure Complete
• N
OTE
•
With master switches OFF, engine will continue to run. However,
no electrical power will be available.
(Continued on next page)
Reissue A