CDB43198-GBK
DS1156DB1
53
6.2.3
Measuring Dynamic Range for the CS43198
To measure dynamic range in WISCE click File->Load and select XTAL_In_ASP_Slave_PCM_Playback_48K_1v7.txt file
from {WISCE_INSTALL_FOLDER}/profiles/CS43198 to configure CS43198 for audio playback in Slave Mode. Note, this
method only works when measuring the CSP device. The QFN device (with mono output) does not interface easily with
the CDB-HDR-MEAS board.
6.2.3.1 Measuring Dynamic Range
The following steps show the procedure to measure dynamic range.
1. Place a jumper connecting the 600-
Ω load on J15.
2. Place a jumper connecting the 600-
Ω load on J4.
3. Connect a headphone cable between CSP-AOUT(J1) and the input of the CDB-HDR-MEAS.
4. Power up the CDB-HDR-MEAS board with ±15V and GND.
5. For each channel, connect a cable between the BNC jacks (Left Channel, Right Channel) and Balanced port on
Analog Inputs 1 and 2 on the APx.
Figure 49 Dynamic Range Setup for CS43198
6. Configure APx and run Dynamic Range Measurement test as described in section 6.2.2.