6.3 Measured Results
This section shows some measured dynamic range and THD+N results from the CDB43198-GBK kit.
6.3.1
Test Waveforms
All test waveforms were generated using the APx Waveform Generator Utility that can be found on the Audio Precision
website.
Table 13 Test Waveforms
Test Type
Waveform Name
Sample Rates
Resolution
Channels
THD+N
Reference Level (0 dB)
44.1 kHz
24 bit
2
DNR
Dynamic Range (1 kHz)
44.1 kHz
24 bit
2
6.3.2
THD+N Results
The table below lists measured THD+N results using the test waveforms under varying load and full-scale voltage
conditions.
Table 14 Measured THD+N Results
Output Load (R
L
)
Full Scale Voltage (VRMS)
Channel
Datasheet Spec (Typical)
Measured Result
1
10k
1.7
A
–115 dB
–113.9 dB
B
–113.6 dB
XLR
–114.4 dB
600
1.7
A
–115 dB
–113.4 dB
B
–113.7 dB
XLR
–114.9 dB
Notes:
1. Refer to CS43198 data sheet for test conditions
6.3.3
Dynamic Range (DNR) Results
The table below lists measured DNR results using the test waveforms under varying load and full-scale voltage
conditions.
Table 15 Measured DNR Results
Output Load (R
L
)
Full Scale Voltage (VRMS)
Channel
Datasheet Spec (Typical)
Measured Result
1
600
1.7
A
130 dB
129.0 dB
2
B
129.1 dB
2
XLR
131.5 dB
Note:
1. Refer to CS43198 data sheet for test conditions
2. Tested with CDB-HDR-MEAS Board
7 Revision History
Revision
Changes
DB1
AUG '18
•
Initial release