51-20
Page 16
All
EFFECTIVITY:
C I R R U S
A I R P L A N E M A I N T E N A N C E M A N U A L
M O D E L S R 2 0
15 Jun 2010
CAUTION:
Care should be taken not to force water further into the structure or to
damage the structure with excessive pressure. Do not exceed gage
pressure of 30 psi.
5
If necessary, use dry compressed air to remove liquid from affected areas.
(b)
Final dry repair area using the following Radiant Heat or Hot Air methods.
(c)
1
Acquire necessary tools, equipment, and supplies.
2
Remove visible liquid.
3
Solvent clean repair area.
4
Install thermocouple(s) at center of heated area.
5
Connect electronic temperature control unit(s) and thermocouple(s).
CAUTION:
Do not cause damage to the structure by over-heating. Ensure heat
lamps are properly calibrated. Do not exceed part temperature of
195° F (91° C) and do not allow air temperature to exceed 200° F (93°
C).
6
Apply required heat to structure ensuring temperature is raised at a rate not greater
than 1.0° - 5.0° F (0.6° - 2.8° C) per minute.
7
Monitor temperature and dry structure for two hours.
8
Remove heat from structure ensuring temperature is lowered at a rate not greater
than 1.0° - 15.0° F (0.6° - 8.4° C) per minute.
9
Let structure cool to room temperature before beginning repair.
(d)
Drying Using Hot Air
To supply heated air, use a hot air dryer with temperature control, or optionally, a dryer
system driven by thermocouples. Do not use hot air dryers without some method of tem-
perature monitoring in place as temperatures achieved may be too high.
1
Acquire necessary tools, equipment, and supplies.
Description
P/N or Spec.
Supplier
Purpose
Cotton Cloth
(clean, lint free)
-
Any Source
Liquid removal.
250 W Heat Lamp(s)
-
Any Source
Liquid removal.
Electronic Temperature
Control Unit
A419ABG-3C Johnson Controls, Inc.
Milwaukee, WI 53201
414-524-4000
Temperature
control.
Infrared Thermometer
MiniTemp MT4
w/ laser point
Raytek Corporation
Santa Cruz, CA 95061
800-866-5478
Temperature
measurement.
Description
P/N or Spec.
Supplier
Purpose
Cotton Cloth
(clean, lint free)
-
Any Source
Liquid removal.