95-01-01
Page 16
All
EFFECTIVITY:
C I R R U S
C O M P O N E N T M A I N T E N A N C E M A N U A L - C A P S
M O D E L S R 2 0
01 Feb 2013
1
Cross upper cord end (end looped around mini-ring) over lower cord end twice. i.e.
right over left, right over left.
2
Cinch nylon cord tight.
3
Tie standard Square Knot and cinch tight.
(m)
Using break thread, sew nylon cord ends together just below CAPS knot.
(n)
Tie CAPS knot with break thread.
CAUTION:
Ensure trimmed ends of nylon cord do not interfere with line cutter’s ignition
loops.
(o)
Trim nylon cord to 1.0 inch (2.5 cm).
(p)
Route line cutter lanyard through line cutter’s ignition loops and secure lanyard to Rapide
link.
(q)
Close hook and loop securing flaps.
(r)
Remove catch cloth from below rocket and parachute assembly.
(s)
Visually inspect parachute compartment for security, leaks, and general condition. (Refer
to AMM 05-20)
(t)
Install access panel CB7 to BH 222. (Refer to AMM 06-00)
(u)
Install BH 222 trim panel and carpet. (Refer to AMM 25-10)