8-24
P/N 13772-005
Section 8
Cirrus Design
Handling and Servicing
SR22T
Battery #2 is a maintenance free, rechargeable, sealed, lead acid
batter. Mounted in the empennage just aft of bulkhead 222, there is no
need to check the specific gravity of the electrolyte or add water to
these batteries during their service life. Refer to the AMM for Overhaul
and Replacement Schedule.
The external power receptacle is located on the left side of the
fuselage just aft of the firewall. Refer to the AMM for battery servicing
procedures.
Oxygen System Servicing
• Caution •
To preclude the possibility of fire by spontaneous combustion,
oil, grease, paint, hydraulic fluid, nd other flammable material
should be kept away from oxygen equipment.
Service the oxygen system per the appropriate revision of the Precise
Flight Instructions for Continued Airworthiness for the Cirrus SR20/
SR22 Built-In Oxygen System, STC number SA01708SE, document
number 102NPMAN0003.
Original Issue