CL-GE300
Rev.900-580-31-00
8.3.
Example 3:
Multiple Cameras/Synchronizing Cameras
RJ
-
4
5
12
p
in
Camera 1
MONO
8 bit
CL- GE 300
C
L1
IN
CL
2
IN
CL
3
IN
GigE
Trigger IN0
Camera 2
MONO
8 bit
Camera 3
MONO
8 bit
Trigger IN0
Camera 1 OUT
Camera 2 OUT
Camera 3 OUT
Camera 3 OUT
GigE OUT
FI
F
O
FI
F
O
FI
F
O
Camera 2 OUT
Camera 1 OUT
Exposure Time
(Camera side: MONO 8bit output, Trigger input: Trigger
IN 0 input)
Recommended
cameras
: VCC-G22/F22PCL series
,
VCC-G32/F32PCL (RAW mode) series
Conditions :
・
Select RAW output cameras when using color cameras.
RGB output cameras shall not be connected.
・
Cameras with same pixels and same frame rate shall be selected.
・
Different triggers cannot be input. Also, different shutter values cannot
be set either.
Camera settings
Address
Data
Remarks
Camera side
Set the camera to trigger mode.
(Refer to the Specifications, address settings for the details.)
When using VCC-G22/F22 PCL series, set the cameras t o HV-SYNC
reset mode.
CL-GE300 side 001
001
CL1 IN, CL2 IN, CL3 IN
-
Trigger IN 0
002 000
8bit
003 000
MONO
004
003
CL1 IN, CL2 IN, CL3 IN Synchronized OUT
©2009 CIS Corporation. All rights reserved.
12