CL-GE300
Rev.900-580-31-00
©2009 CIS Corporation. All rights reserved.
14
9.
Function Settings
With serial communications via LAN or 12pins circular connector RS-232C port, both cameras and
CL-GE 300 functions can be set.
(1)
Serial communication settings are as follows.
Baud rate
:
9600bps
Data
:
8bit
Stop bit
:
1bit
Parity
:
None
XON/XOFF
: not controlled
(2)
Control code
・
The total control code is 14 bits, which conforms to ASCII code.
・
The control code consists of camera No. process code, remote controller address, remote
controller data, and CR. Execute Read/Write through PC, and the camera will reply the data.
1 2 3 4 5 6
7
th Byte
8 9 10 11 12
13
14
Camera No.
Process code
Remote
controller
address
Remote
controller data
CR
000000
:
to CL1
IN
100000
:
to CL2
IN
200000
:
to CL3
IN
300000
:
to all (CL1 IN/2 IN/3 IN)
400000
:
to CL-GE300
“R” Read mode
Please refer to
the address
table, in Section
5.
000
~
255
0Dh
“W” Write mode
“C” Camera mode
10.
Initial Settings
Functions Address
Data
Internal Trigger Cycle
000
0:OFF
Trigger Input Selection
001
0:CL1 IN-Trigger IN 0,CL2 IN-Trigger IN 1,CL3 IN-Trigger IN 2
10bit/8bit Selection
002
0:8bit
RGB/MONO(RAW) Selection 003
0:MONO(RAW)
Output Channel Selection
004
0:CL1 IN OUT