CL-GE300
Rev.900-580-31-00
(11)
Durability
Vibration
resistance
Acceleration :
98m/s
2
(10G)
Vibration
frequency
: 20
~
200 Hz
Direction :
X,Y,Z
3directions
Testing time
: 120 min for each direction
Shock resistance
Acceleration
: 490m
/
s
2
(50G)
Directions
:
±
X,
±
Y, and
±
Z 6 directions
*Without package
(12)
Operation Environment
Temperature
Performance guaranteed temperature: 0
℃~
+40
℃
Camera operation guaranteed temperature: -5
℃~
+45
℃
※
All the specifications specified in this manual is
guaranteed under performance guaranteed temperature.
※
All the camera functions operate normally under operation
guaranteed temperature
Humidity
RH 20
~
80% with no condensation
(13)
Storage Environment
Temperature
-25
℃
~
+60
℃
Humidity
RH 20
~
80% with no condensation
5. Function Settings
Function Address
Data
Internal Trigger Cycle
000
0 : OFF
1 – 255 : 888
μ
s + (444
μ
s
x
n)
Trigger Input Selection 001
0 : CL1 IN – Trigger IN 0, CL2 IN – Trigger IN 1,
CL3 IN – Trigger IN 2
1 : CL1 IN , CL2 IN , CL3 IN – Trigger IN 0
2 : CL1 IN , CL2 IN , CL3 IN – Internal Trigger
Generated in the CL-GE300 (Cycle :
Address 000)
3 :CL1 IN , CL2 IN , CL3 IN – Software Trigger
10bit / 8bit Selection
002
0 : 8bit
1 :10bit
※
Valid only at MONO (RAW) setting.
RGB/MONO(RAW)
Selection
003
0 : MONO(RAW)
1 : RGB
Output Channel
Selection
004
0 : CL1 IN OUT
1 : CL2 IN OUT
2 : CL3 IN OUT
3 : CL1 IN , CL2 IN , CL3 IN Synchronized OUT
4 : RGB OUT
5
– 7 : CL1 IN OUT
©2009 CIS Corporation. All rights reserved.