VCC-5CL1R
Rev. 905-0022-02
©2015 CIS Corporation. All rights reserved.
6
(19)
Partial Scan
Vertical: 2
~
2048 lines (2 lines/step)
Horizontal: 2560 pixels, 2048 pixels, 1920 pixels
(20)
Sequence function
8 parameter set.
Start X, Y coordinate, Horizontal size, Vertical size, Exposure, Gain settings,
Trigger pulse control, and CC line control.
(21)
Safety/Quality standards
UL: Conform to UL Standard including materials and others.
CE:
EN55022:2010 (Class A) for Emission
EN61000-6-2:2005 for Immunity
RoHS:
Conform to RoHS.
(22)
Durability Vibration
Acceleration
: 98m/s
2
(10G)
Frequency
: 20
~
200 Hz
Direction
: X,Y, and Z 3 directions
Testing time
: 120min for each direction
Shock
No malfunction shall occur with 980m/s
2
(100G) for
±
X,
±
Y, and
±
Z,
6 directions. (without package)
(23)
Operation environment
Temperature
Performance guaranteed temperature: 0
℃
~ +40
℃
with no
condensation
※
All the specifications specified in this manual are guaranteed under
performance guaranteed temperature.
Camera operation guaranteed temperature: -5
℃
~ +45
℃
with no
condensation
※
All the camera functions operate normally under operation guaranteed
temperature.
Humidity
RH 20
~
80% with no condensation.
(24)
Storage Environment
Temperature
-25
℃
~ +60
℃
Humidity
RH 20
~
80% with no condensation.