VCC-5CL4MHS
Rev.905-0079-01
©2017 CIS Corporation. All rights reserved.
22
□
White Defects Detection by the users. (Address 100).
This is the function to register the pixels automatically if a pixel exceeds the level specified by the user.
Please be noted that no lights should be in the sensor surface to use this function.
There are 2 kinds of parameters for commands.
The First Parameter:
Threshold (0
~
1023)
The data with luminance level more than the specified level here shall be registered.
※
In case of 8bit images, 4 times value of the image signal level shall be specified as the
threshold value.
The Second Parameter: Additional Flag (0, 1)
When 0 is specified, all of user’s white defects data registered by that time are cleared out,
and data will be newly registered.
When 1 is specified, only newly detected white defects data will be added to the old data
registered by that time.
Even when the Additional Flag 0 is specified, the added data with the Address 101 would not be deleted.
□
Additional registration of defected pixels by users (Address 101).
This is the function to register any defected pixels specifying its coordinate.
There are 2 parameters as commands.
The first parameter
:
X Coordinate
The second parameter
:
Y Coordinate
When the same defected pixel as the one registered at our Ex-factory was specified, it shall be ignored.
□
Deletion of defected pixels data registered by users (Address 102).
This is the function to delete the defected pixels data detected and registered by the users.
There are 2 parameters as commands.
The first parameter
:
X Coordinate
The second parameter
:
Y Coordinate
Only the registered data by users, with Address 100 or Address 101, can be deleted.
The data registered at our Ex-factory cannot be deleted by this command.
□
Entire deletion of defected pixels data registered by users (Address 103).
This is to delete all defected pixels data detected and registered by the users, with Address 100 and Address 101.
Please execute this when you wish to redo your detection and registration from the beginning, or when you wish to
restore all the registration to the factory settings. SU 103 1 to execute