9.4 Burst Mode
The start and stop of sequence operation can be controlled by the edge control or level control of trigger input signals,
and register start.
・
S
et TriggerSelectorAndActivation to FrameBurstStart.
(1). Edge Control
TRIG IN
Video Out
Effective Line
Exposure
Effective Line
①
FVAL Out
②
Sequence Control Start
Sequence Control Finish
Effective Line
Effective Line
Effective Line
①
・
S
et SequencerActivation to FrameBurstStartEdge to start sequence operation by inputting a trigger.
・
Exposure time (
①
) and output frame time (
②
) for each frame shall be controlled by the preset sequence parameter
set and link configuration settings.
・
When the image output for the sequence Loop count is completed, sequence operation ends.
(2). High Level Control
TRIG IN
Video Out
Effective Line
Exposure
Effective Line
①
FVAL Out
②
Sequence Control Start
Sequence Control Finish
Sequence Control Stop
Sequence Control ReStart
Effective Line
Effective Line
Effective Line
①
・
S
et SequencerActivation to FrameBurstStartLevel to start sequence operation while trigger input is at high level.
・
Sequence operation can be paused by changing the trigger input to Low level. If you wish to end Sequence
operation, turn OFF sequence control.
・
By changing the trigger input to High level, Sequence operation can be resumed.
・
When the image output for the sequence Loop count is completed, sequence operation ends.
(3). Resister Start
・
Sequence operation starts at the same time when SequencerActivation is turned off and FrameBurstStartSoftware is
set.
※