background image

VCC-SXCXP3M                                                                                                                                      Rev. 905-0049-00 

 

©2017 CIS Corporation. All rights reserved. 

22 

 
9.4 Burst Mode 
 

The start and stop of sequence operation can be controlled by the edge control or level control of trigger input signals, 
and register start. 

 

S

et TriggerSelectorAndActivation to FrameBurstStart. 

 

(1).  Edge Control 
 

TRIG IN

Video Out

Effective Line

Exposure

Effective Line

FVAL Out

Sequence Control Start

Sequence Control Finish

Effective Line

Effective Line

Effective Line

 

 

 

S

et SequencerActivation to FrameBurstStartEdge to start sequence operation by inputting a trigger. 

 

Exposure time (

) and output frame time (

) for each frame shall be controlled by the preset sequence parameter 

set and link configuration settings. 

 

When the image output for the sequence Loop count is completed, sequence operation ends. 

 

(2).   High Level Control 
 

TRIG IN

Video Out

Effective Line

Exposure

Effective Line

FVAL Out

Sequence Control Start

Sequence Control Finish

Sequence Control Stop

Sequence Control ReStart

Effective Line

Effective Line

Effective Line

 

 

S

et SequencerActivation to FrameBurstStartLevel to start sequence operation while trigger input is at high level. 

 

Sequence  operation  can  be  paused  by  changing  the  trigger  input  to  Low  level.    If  you  wish  to  end  Sequence 
operation, turn OFF sequence control. 

 

By changing the trigger input to High level, Sequence operation can be resumed. 

 

When the image output for the sequence Loop count is completed, sequence operation ends. 

 
(3). Resister Start

 

 

 

Sequence operation starts at the same time when SequencerActivation is turned off and FrameBurstStartSoftware is 
set.     

 

To restart burst mode operation, turn off SequencerActivation OFF once. 

 
 

 

Summary of Contents for VCC-SXCXP3M

Page 1: ...VCC SXCXP3M Rev 905 0049 00 2017 CIS Corporation All rights reserved CoaXPress I F 1 3M CMOS B W Camera VCC SXCXP3M Product Specifications Operational Manual CIS Corporation English...

Page 2: ...Operational Mode 8 7 1 Link Configuration 8 7 2 Pixel Format 8 7 3 Camera Sync Mode 8 7 3 1 Internal Sync Mode Free Run Mode 9 7 3 2 External Trigger Sync Mode 9 8 Function Settings 12 8 1 Gain Settin...

Page 3: ...SXCXP3M Rev 905 0049 00 2017 CIS Corporation All rights reserved 2 11 Dimensions 27 11 1 Optical Axis Accuracy 27 11 2 Camera Dimensions 28 12 Case for Indemnity Limited Warranty 29 13 Product Support...

Page 4: ...nnector Pin Assignment for connecting the camera module Improper connection may cause damages not only to the camera module but also to the connected devices Confirm the mutual ground potential carefu...

Page 5: ...tial Scan ROI 5 Preset patterns Quad VGA 1K1K XGA SVGA VGA 16 Power Requirements PoCXP 17 Power Consumption 2 5W CXP 1 2 7 W CXP 2 CXP 3 entire pixels at free run 18 Dimensions H 29mm W 29mm D 29mm wi...

Page 6: ...8bit Setup Level 01 01h At MONO 8bit Gain 0dB Setup level changes when gain is increased It is adjustable by changing black level or Black Off set 5 External Trigger Signal Input CoaXPres BNC Connecto...

Page 7: ...Japan Aviation Electronics Industry Limited 5 2 6 pins Circular Connector SNH 8 6 RPCB SamWoo Electronics Pin No Signals Note 1 NC 2 NC 3 SIGNAL_OUT The output of the selected signal 4 NC 5 TRIGGER_IN...

Page 8: ...V CMOS level input TTL compatible Input voltage Low 0 5Vdc Min High 2 1Vdc Max 6 How to Save and Initialize the Settings UserSetControl UserSetSave Execute UserSetDefault Execute Settings shall be res...

Page 9: ...ive FrameBurstStart Internal sync mode Burst mode of sequence function TriggerSource This is to set how to input triggers of external trigger sync mode CXP_Host This is to use Low Speed uplink of CoaX...

Page 10: ...e CXP_Host Approx 3 4 s LineIn Approx 150 ns Notes for trigger pulse input timing The next trigger pulse can be input while reading out signals However please do not input a trigger pulse which ends i...

Page 11: ...s the mode to start exposure by the input trigger signals and to set its exposure time manually or with preset Set TriggerSelectorAndActivation to FrameStartRisingEdge or FrameStartFallingEdge Trigger...

Page 12: ...rigger cycle needs to be longer than FVAL period 1 framerate Trigger operation is CLK Sync H V Sync Reset The minimum pulse width shall be 100 s Functionally there is no upper or lower limitation Howe...

Page 13: ...e reduced when gain setting is increased We recommend you to evaluate it first AnalogControl PresetGainX Gain_x1 Gain_x1_5 Gain_x2 Gain_x3 Gain_x4 Gain_x6 Gain_x8 Gain Manual Preset gain GainMode When...

Page 14: ...hutter_1_150 1 150 6 7 ms Shutter_1_300 1 300 3 3 ms Shutter_1_600 1 600 1 7 ms Shutter_1_1200 1 1200 833 us Shutter_1_2500 1 2500 400 us Shutter_1_5000 1 5000 200 us Shutter_1_10000 1 10000 100 us Ex...

Page 15: ...OI mode and exposure timing Setting mode Pixels Known as Frame rate fps CXP 1 CXP 2 CXP 3 ROIQuickChangeOff 1280x1024 SXGA 8bit 84 0 167 8 167 8 10bi 67 7 135 5 167 8 ROIQuickChangePattern1 1280x960 Q...

Page 16: ...d with ROI mode Execute re grabbing the viewer to acquire images The frame rate when sub sampling operation is performed at free run mode shall be as follows 8 5 Defective Pixel Correction CIS compens...

Page 17: ...ideo output at trigger mode operation it cannot operate properly To operate DetectShading properly a trigger signal shall be input within 200ms after execution Shading Correction Turn ShadingCorrectio...

Page 18: ...its lighting Lighting Status Camera Status OFF No PoCXP Supplied Green Slow Blinking 0 5Hz Confirmed connection of the device and the host Green Lighting Transmitting video data Orange Slow Blinking 1...

Page 19: ...own as Hi Active FrameActive The effective period of the frame is to be shown as Hi Active LineActive The effective period of the line is to be shown as Hi Active TriggerPacketActive Uplink trigger pa...

Page 20: ...de 2 Settings of Sub sampling and ROI Turn OFF SubsamplingMode ROI of ImageFormatControl shall be ROIQuickChangeOff These are invalid with sequence control function 3 Settings of parameter table for s...

Page 21: ...status of the parameter set To restart burst mode operation turn OFF SequencerActivation once Turn SequncerActivation OFF to return to the status before sequence control function was operated 9 2 Tri...

Page 22: ...tarts with trigger input when TriggerSelectorandActivation is FrameStartRisingEdge or FrameStartFallingEdge Exposure time for each frame and shall be controlled by the preset sequence parameter set Wh...

Page 23: ...for the sequence Loop count is completed sequence operation ends 2 High Level Control TRIG IN Video Out Effective Line Exposure Effective Line FVAL Out Sequence Control Start Sequence Control Finish S...

Page 24: ...parameter set 2 Pulse Width Control Trigger Pulse Width becomes exposure time for each frame Exposure time of the parameter set is not referred As to the timing to issue IndexSelectorModeIndexNumber c...

Page 25: ...he low level control of the trigger pulse FrameBurstStart Set sequence control to use at burst mode Settings for Sequence Mode Start SequencerControl SequencerActivation OFF FrameStartPredefined Frame...

Page 26: ...status information of Sequence burst mode 0 Executing 1 Completion IndexNumberStatus Indicate the Index number in execution RepeatNumberStatus Indicate the Index repeating count in execution LoopNumb...

Page 27: ...ensorHeight 1024 ROIOff SubsamplingMode Subsampling_Off PixelFormat Mono8 TestImageMode OFF AquisitionControl TriggerSelectorAndActivation AcquisitionMode TriggerSource LinkTrigger0 ExposureTime 3333...

Page 28: ...VCC SXCXP3M Rev 905 0049 00 2017 CIS Corporation All rights reserved 27 11 Dimensions 11 1 Optical Axis Accuracy...

Page 29: ...VCC SXCXP3M Rev 905 0049 00 2017 CIS Corporation All rights reserved 28 11 2 Camera Dimensions...

Page 30: ...damages or losses are caused by deliberate or accidental misuse by the user or failure to observe the information contained in the instructions in this Product Specification and Operational Manual In...

Reviews: