9.6 Settings for Sequence Control
Execute UserSetSave to save the settings. SequencerActivation is not saved so that it will always be OFF when power is
turned ON. Settings shall be set every time when using Sequence mode.
□
How to set Sequence Control Settings.
Acquisition Control
TriggerSelectorAndActivation
AquisitionMode
FrameStartRisingEdge
FrameStartFallingEdge
FrameStartLevelHigh
FrameStartLevelLow
FrameBurstStart
・
FrameStartRisingEdge
:
Set sequence control to the rising edge control of the trigger pulse.
・
FrameStartFallingEdge
:
Set sequence control to the falling edge control of the trigger pulse.
・
FrameStartLevelHigh
:
Set sequence control to the high level control of the trigger pulse.
・
FrameStartLevelLow
:
Set sequence control to the low level control of the trigger pulse.
・
FrameBurstStart
:
Set sequence control to use at burst mode.
□
Settings for Sequence Mode Start
SequencerControl
SequencerActivation
OFF
FrameStartPredefined
FrameStartIndexSelector
FrameBurstStartEdge
FrameBurstStartLevel
FrameBurstStartSoftware
・
FrameStartPredefined
:
Set to start trigger mode
and burst mode.
・
FrameStartIndexSelector:
Set to start index mode.
・
FrameBurstStartEdge:
Set to start burst mode with edge control.
・
FrameBurstStartLevel:
Set to start burst mode with High level control.
・
FrameBurstStartSoftware:
Set to start burst mode with register start.
□
Settings for Sequence Count and Range
SequencerConfigurationParameter
Setting Range
SequencerLoopCount
Loop count for whole sequence.
1-1023
0: infinity
ActiveIndexNumber
The largest Index number to execute.
0-7
IndexSelectorModeIndexNumber
The Index number to use for Index Mode.
0-7
ParameterIndexNumber
Index0-7
Parameter number of Index 0-7.
0-7
IndexLoopCount
IndexCount0-7
Repeating count of each Index 0-7.
0-7