9 10
LVAL output
FVAL output
DVAL output
Video Output
Exposure Time
Read OUT Signals
Discharge
Signals
9
H
a
11 12
SP output
c
"L"
"H"
"L"
"H"
"L"
"H"
"L"
"H"
b
b
7.
Timing Chart
7.1. Horizontal Synchronous Signal Timing
206CLK
192CLK
1790CLK
LVAL Signal Output
Video Signal Output
1360CLK
16CLK
16CLK
Active Area
DVAL Signal Output
7.2. Vertical Synchronous Signal Timing
7.2.1. Normal Shutter Mode (Trigger Shutter Mode OFF)
* Recommended numbers of output lines at full frame scan mode is 1024H dividing at the center.
Scan Mode
a line
number
b line
number
c line
number
Total line
numbers
Full Frame Scan Mode
8 H
1040 H
11 H
1068 H
Partial Scan Mode 1
29 H
770 H
27 H
835 H
Partial Scan Mode 2
50 H
560 H
48 H
667 H
Partial Scan Mode 3
65 H
410 H
63 H
547 H