VCC-F22S29ACL
Rev.900-636-32-00
©2010 CIS Corporation. All rights reserved.
14
Fixed Trigger Shutter Mode
LVAL output
FVAL output
DVAL output
Read OUT signal
Video Signal
Discharge signal
Trigger Input
1
9H
a
Exposure Time
b
c
SP output
Pulse Width Trigger Shutter Mode
LVAL output
FVAL output
DVAL output
Read OUT signal
Video Signal
Discharge signal
Trigger Input
1
9H
a
Exposure Time
b
c
SP output
Re-Trigger Input
Cancell Area
Re-Trigger Input
Cancell Area
7.2.2. Trigger Shutter Mode
CLK- Synchronous Mode Details at Pulse Width Trigger Shutter Mode
Scan Mode
a line
number
b line number
c line
number
Total line
numbers
Full Frame Scan Mode
8 H
1040 H
11 H
1068 H
Partial Scan Mode 1
29 H
770 H
27 H
835 H
Partial Scan Mode 2
50 H
560 H
48 H
667 H
Partial Scan Mode 3
65 H
410 H
63 H
547 H