background image

VCC-F22U29APCL  

Rev.900-675-31-00

 

 

©2009 CIS Corporation. All rights reserved. 

 

16

Inclination of optical 
axis to datum plane

29

12

Datum 
Plane

M2

M3

M2

29

29

The center of effective pixels shall be
Within f 0.6 to the center of lens mount.

Inclination of effective pixles? to datum 

plane shall be 

?? ±0.5°

(*) Dimensions from datum plane to the center of lens mount.

910-007-01-01

Datum Plane

Product Name Plate Position( ? )

(Unit :mm)

±

0.

6±0.3

6±0.3

14

.5±0

.3(*

)

6±0.3

6±0.3

10±0.3

10±0.3

±

0.5

°

10.    CCD Optical Axis Accuracy 

 

 

Summary of Contents for Vision:mini VCC-F22U29APCL

Page 1: ...CC F22U29APCL Rev 900 675 31 00 2009 CIS Corporation All rights reserved UXGA Color Camera 49MHz Pixel Clock PoCL PoCL Lite VCC F22U29APCL Product Specification Operational Manual CIS Corporation English ...

Page 2: ...Response Representative value 8 5 Function Settings 9 6 External Connector Pin Assignment 11 7 Timing Chart 12 7 1 Horizontal Synchronous Signal Timing 12 7 2 Vertical Synchronous Signal Timing 12 7 2 1 Normal Shutter Mode Trigger Shutter Mode OFF 12 7 2 2 Trigger Shutter Mode 13 8 Remote Interface Function 14 9 Initial Settings 15 10 CCD Optical Axis Accuracy 16 11 Dimensions 17 12 Cases for Inde...

Page 3: ... subject to fluorescent light reflections Places subject to unstable flickering etc lighting conditions Places subject to strong vibration z Remove dust or dirt on the surface of the lens with a blower z Do not apply excessive force or static electricity that could damage the camera z Do not shoot direct images that are extremely bright e g light source sun etc and when camera is not in use put th...

Page 4: ... can be read out within approx 1 20s Interface of F22U29APCL complies with camera link standard Key Features Either PoCL or PoCL Lite interface output can be selectable Camera settings can be changed via serial communications Selectable RAW and RGB 8 bit or 10 bit 1 20 1 40 000s shutter speeds can be set per 1H Full frame scan mode and three different partial scan modes are available Approx 20 fps...

Page 5: ... lines Resolving power 8bit 10bit at RAW data output 8 bit at RGB data output Sensitivity F5 6 2000 lx Shutter 1 20s Gain 0dB Minimum illumination F1 4 20 0 lx Shutter 1 20s Gain 12dB Dust or stains in optical system No dust or stain shall be detected on the testing screen with setting the camera aperture at F16 Power requirements DC 12V 10 Max voltage not to exceed 15V Power consumption 2 7 W DC ...

Page 6: ... two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Durability Vibration Acceleration 98 m s2 10 0G Frequency 20 200 Hz Direction XYZ 3 directions Testing time 120 min for each direction Shock No malfunction shall be occurred with 490m s2 50G for X Y and Z 6 directions wit...

Page 7: ...AL output LVDS HD VD input None Trigger input Polarity POSI NEGA Selectable Min Trigger Pulse width Over 1 HD Camera Link input LVDS CC1 input Camera Link connector Video output signal White Clip Level Digital 8bit FFh Digital 10bit 3FFh Setup Level Digital 8bit 08 03h Digital 10bit 020 00Ch RAW Data Output Details DVAL Horizontal DVAL Vertical R G R G R G R G G B G B G B G B R G R G R G R G G B G...

Page 8: ...VCC F22U29APCL Rev 900 675 31 00 2009 CIS Corporation All rights reserved 8 4 3 CCD Spectral Response Representative value Lens characteristics and illuminant characteristics are not considered ...

Page 9: ...RAW data output 3200K 6 RGB data output 3200K 2 RAW data output spare 7 RGB data output spare 3 RAW data output spare 8 RGB data output spare 4 RAW data manual white balance 9 RGB data manual white balance Trigger Mode 004 0 Normal Shutter Mode Trigger Shutter Mode Off 1 Fixed Trigger Shutter Mode Shutter speed can be set with address 002 2 Pulse Width Trigger Shutter Mode Shutter speed can be set...

Page 10: ...t change Output Data Selection 013 0 Set the data of Address 003 to 000 004 RAW 8 bit output data 8 bit output data 1 RAW 10 bit output data 2 PoCL Lite RAW 8 bit output data 3 PoCL Lite 10 RAW bit output data Trigger Reset Mode 014 0 H Synchronous Mode 1 CLK Synchronous Mode Data Save 015 Input 083 to save address 000 014 into EEP ROM Note Please note the followings when using trigger shutter mod...

Page 11: ...nnector Pin Assignment 26pins camera Link connector 12226 1100 00 PL SUMITOMO 3M Pin No Pin No 1 DC 12V 14 GND 2 X0 15 X0 3 X1 16 X1 4 X2 17 X2 5 Xclk 18 Xclk 6 X3 19 X3 7 SerTC 20 SerTC 8 SerTFG 21 SerTFG 9 CC1 Trigger IN 22 CC1 Trigger IN 10 CC2 23 CC2 11 CC3 24 CC3 12 CC4 25 CC4 GND 13 GND 26 DC 12V ...

Page 12: ... LVAL Signal Output Video Signal Output 1600CLK 14CLK 14CLK Active Area DVAL Signal Output 7 2 Vertical Synchronous Signal Timing 7 2 1 Normal Shutter Mode Trigger Shutter Mode OFF Recommended number of output lines b line at full frame scan mode is 1200H dividing at the center Scan Mode a line number b line number c line number Total line numbers Full Frame Scan Mode 7 H 1236 H 0 H 1252 H Partial...

Page 13: ... Area 9H 9H Trigger Input LVAL output FVAL output DVAL output SP output Discharge signal Read Out signal Video Signal Exposure Time Re Trigger Input Cancell Area 7 2 2 Trigger Shutter Mode CLK Synchronous Mode Details at Pulse Width Trigger Shutter Mode Scan Mode a line number b line number c line number Total line numbers Full Frame Scan Mode 7 H 1236 H 0 H 1252 H Partial Scan Mode 1 29 H 964 H 2...

Page 14: ...individual camera R Read mode Please refer to the address table of 5 Function Settings 000 255 0 Dh W Write mode C Camera mode Camera No shall consist of 6 bytes of characters numeric strings Send the individual camera number code or common number code 000000 The reply data from the camera shall contain the registered number for that camera Process code Input any one of R W or C to the process cod...

Page 15: ...o input CR to confirm the end of the command 10ms should be waited to send the next command after receiving the response from the camera when changing the mode in succession 9 Initial Settings Gain 001 1 0dB E Shutter 002 0 1 20s Off White Balance 003 6 RGB data output 3200K Trigger Mode 004 0 Normal Shutter Mode Trigger Shutter Mode Off Scan Mode 005 0 Full Frame Scan Mode Manual White Balance R ...

Page 16: ...29 29 The center of effective pixels shall be Within f 0 6 to the center of lens mount Inclination of effective pixles to datum plane shall be 0 5 Dimensions from datum plane to the center of lens mount 910 007 01 01 Datum Plane Product Name Plate Position Unit mm 0 2 6 0 3 6 0 3 14 5 0 3 6 0 3 6 0 3 10 0 3 10 0 3 0 5 10 CCD Optical Axis Accuracy ...

Page 17: ... 5 999 519 00 00 3 4 5 12 20 22 Product Name Label Position M2 Size Unit mm 2 M2 Depth 3 C M o u n t F 28 3 M3 Depth 3 23 7 M3 Size 4 M2 Depth 3 C Mount screws comply with ANSI ASME B1 1 1 32UN 2B Screw length from C mount lens surface shall be under 6mm And protruding portion shall be less than 10mm 11 Dimensions ...

Page 18: ...of malfunction or non function of the equipment we shall be exempted from responsibility for such damages In case damage or losses are caused by failure to observe the information contained in the instructions in this product specification operation manual In case damage or losses are caused by use contrary to the instructions in this product specification operation manual In case damage or losses...

Page 19: ...ou would like us to investigate on the cause and repair please contact your distributors you purchased from to consult and coordinate Control SW Sample software for camera control RS 232C can be downloaded from our home page URL http www ciscorp co jp We shall be exempted from taking responsibility and held harmless for damage or malfunction of your hardware and software caused by using this contr...