![background image](http://html.mh-extra.com/html/cisco/3600-series/3600-series_hardware-installation-manual_64347286.webp)
26-2
Cisco Network Modules Hardware Installation Guide
OL-2485-20
Chapter 26 Connecting NAM Enhanced Network Modules
NAM Enhanced Network Modules
Figure 26-1 NME-NAM-80S Faceplate
f
CF
Status of the CompactFlash
Off—CompactFlash is not used
Flashing—Application detected CompactFlash at boot up
SHUTDOWN
Press the SHUTDOWN button for less than 2 seconds to gracefully shut down the
module. Press the SHUTDOWN button for more than 4 seconds to cause an immediate
module shutdown, which may impact file operations that are in progress.
LINK
Status of Gigabit Ethernet link
On—Link is enabled
Off—Link is disabled
ACT
Status of Gigabit Ethernet activity
On—Active
Off—Inactive
DISK
Status of hard drive activity
On—Active
Off—Inactive
SYS
Status of system shutdown
Note
Do not remove power without first shutting down the application.
On—Application is stable.
Off—System is shut down and ready for host power down
Flashing—System shutdown is in progress
EN
Status of the enhanced network module
On—Detected by the host Cisco IOS software and enabled
Off—Disabled
230226
SHUTDOWN:
GRACEFUL <1 s
IMMEDIATE >4 s
CF
LINK
ACT
SYS
DISK
EN
GigE
USB
NOT
SUPPORTED
NME-NAM-80S
XXX-XXXXX-XX XX
CF
Shutdown
LINK
ACT
DISK
SYS
CF card
EN
Never remove compact
flash during operation
Shut down
application
before removing or
power cycling.