B-22
Cisco AS5400 Universal Gateway Chassis Installation Guide
OL-2847-02 0A
Appendix B Replacing the Power Supply
Configuring the Power Supply Alarm
Verify Alarm Configuration
To verify the status of the alarm configuration, enter the
show facility-alarm
command:
5400#
show facility-alarm
Device State
------ -----
FastEthernet0/0 UP
Modem Card 4 UP
Facility Alarm is ON
Note
For information on connecting alarm devices to the alarm port on the
Cisco AS5400, refer to the
Cisco AS5400 Universal Gateway Chassis Installation
Guide.
Step 2
Router#
configure terminal
Enter global configuration mode.
Step 3
Router(config)#
facility-alarm detect
rps
Turns on alarm when a redundant power supply
failure is detected. Any of the following failures
will turn on the alarm:
•
I/P voltage failure
•
O/P voltage failure
•
Overvoltage condition
•
Multiple failures
Step
Command
Purpose