1-14
Cisco ASA 5580 Series Adaptive Security Appliance Hardware Installation Guide
OL-12920-01
Chapter 1 Introduction to the ASA 5580
Specifications
In a failover configuration, the two units must have the same hardware configuration. They must be the
same model, have the same number and types of interfaces, and the same amount of DRAM.
Note
The two units do not have to have the same size flash memory. If using units with different flash memory
sizes in your failover configuration, make sure the unit with the smaller flash memory has enough space
to accommodate the software image files and the configuration files. If it does not, configuration
synchronization from the unit with the larger flash memory to the unit with the smaller flash memory
will fail.
Rated input power
1161W @ 100 VAC
1598W @ 200 VAC
Rated input current
12A (100 VAC)
8A (200 VAC)
Maximum heat dissipation
3960 BTU/hr (100 VAC)
5450 BTU/hr (200 VAC)
Power supply output
910 W (low line)
1300 W (high line)
Environment
Temperature
Operating 50 to 95°F (10 to 35°C)
2
Nonoperating -40°F to 158°F (-40°C to 70°C)
Maximum wet bulb temperature
82.4°F (28°C)
Relative humidity
(noncondensing)
Operating 10% to 90%
Nonoperating 5% to 95%
Altitude
Operating 0 to 6500 ft (2000 m)
Nonoperating 0 to 30,000 ft (9144 m)
Shock
Operating Half-sine 2 G, 11 ms pulse, 100 pulses
Nonoperating 25 G, 170 inches/sec delta V
Vibration
2.2 Grms, 10 minutes per axis on all three axes
1.
With full card installation and two power supplies.
2.
At sea level with an altitude derating of 1.8
°
F per every 1000 ft (1.0
°
C per every 3.0m) above sea level to a maximum of
10,000 ft (3050 m). no direct sustained sunlight.
Table 1-5
ASA 5580 Specifications (continued)