15
Standards and Certifications
OL-2186-01
Standards and Certifications
Step 8
Use a flat-head screwdriver to screw in the Champ connectors and tie wrap the connector to the chassis,
as shown in
Figure 6
Attaching the Champ Connector the Chassis
Step 9
Plug the AC power cord into the wall outlet or reinsert the fuses in the fuse and alarm panel.
Step 10
Set the circuit breaker on the DC PEM to the ON (1) position.
Standards and Certifications
The DSL interface module has the same standards as the Cisco 6015 system, as shown in
1
Champ connector screw
3
Champ connector
2
Tie wrap
48039
2
3
1
Table 3
Regulatory Compliance for Cisco 6015 Hardware
Area of
Compliance
Compliance Standard
Product Safety
UL 1950, 3rd Edition, EN 60950, AS/NZS 3260, IEC 950,
FCC Part 15, Class B
Emissions
CISPR22, EN55022, AS/ANS 3548, ICES-003, VCCI, BSMI (CNS 13438)
Immunity
EN61000-4-2, 3, 4, 5 and 6 / IEC-61000-4-2, 3, 4, 5 and 6;
EN61000-4-11 / IEC-61000-4-11
NEBS
Bellcore GR-63-CORE, GR-1089-CORE, SR-3590 Level 3
Telecom
FCC Part 68, CS-03, ACA TS 016: 1997, CTR 12 97/520/EC
Amendment 1 1997 (TBR 12), JATE GREEN BOOK 1997
ETSI
300-386-1, 300-386-2, 300-019