Cisco 6100 Thermal Upgrade Kit Installation Procedures
78-10158-01
Installing the Cisco 6100 Thermal Upgrade Kit
Figure 3
Power Connections for the Cisco 6100—Single-Power Feed
Disconnect the Cisco 6100 from the Cisco 6120
If you need to prepare the rack to accommodate the fan tray and install the thermal guard, you will need
to disconnect the Champ cables from the Cisco 6100 (connectors J39 through J44) to the Cisco 6120
(connectors J1 through J6). Table 6 shows the corresponding Cisco 6100 and Cisco 6120 connectors.
1 2 3 4 5 6 7 8 9 10
Cisco 6130
P13
-48V_A
-48RTN
-48V_B
-48RTN
NEG
NEG
POS
POS
NEG DC
NEG DC
POS RTN
POS RTN
B
A
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
18394
Table 6
Cisco 6100 and Cisco 6120 Corresponding Connectors
Cisco 6100
Connector
Cisco 6120
Connector
J39
J3
J40
J1
J41
J5
J42
J4
J43
J2
J44
J6